Evidence map›Paper›PMID 41816633›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2026

Time-of-Flight Requirements to Mitigate Blurring Induced by Annihilation Photon Acollinearity.

Maxime Toussaint, Francis Loignon-Houle, Jean-Pierre Dussault, Roger Lecomte

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Maxime ToussaintSherbrooke Molecular Imaging Center, CRCHUS, and the Department of Medical Imaging and Radiation Sciences, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada.ORCID 0000-0003-3402-8186
Francis Loignon-HouleInstituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0001-8931-2016
Jean-Pierre DussaultDepartment of Computer Science, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada.ORCID 0000-0001-7253-7462
Roger LecomteSherbrooke Molecular Imaging Center, CRCHUS, and the Department of Medical Imaging and Radiation Sciences, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada, and also with IR&T, Sherbrooke, QC J1K 0A5, Canada.ORCID 0000-0002-8541-0783

Funding

Ultra High Resolution Brain PET Scanner for in-vivo Autoradiography ImagingU01EB027003 · NIBIB · YALE UNIVERSITY · PI EL FAKHRI, GEORGES, FONTAINE, RÉJEAN · 2018 to 2022
$4.6M
NIBIB NIH HHS U01 EB027003
6 · The paper itself

Abstract

One of the limiting factors of spatial resolution in positron emission tomography (PET) imaging is annihilation photon acollinearity (APA). For whole-body PET scanners, APA induces a blur ranging from 1.7 to 2.2 mm FWHM. For long axial field-of-view (FOV) scanners, this range increases even more, depending on the maximum ring difference. It was previously shown that perfect time-of-flight (TOF) resolution sharpens the APA-induced blur by altering its expected Gaussian shape into a profile resembling a 1/r function, thereby reducing its contribution to spatial resolution loss. This suggests that the conventional theoretical limit of PET spatial resolution could be overcome if sufficient TOF resolution can be achieved. However, the requirements to achieve an observable gain in spatial resolution have yet to be explored. We propose an investigation of these requirements for whole-body and long axial FOV scanners, in terms of TOF resolution and count statistics. Using a fictive 81-cm diameter scanner with 2-mm wide detectors, we show that ultrafast TOF resolution-13 ps FWHM-enables an observable gain in spatial resolution for a range of count statistics. In addition, we show that lower TOF resolutions (i.e., higher TOF values of 27 or 67 ps) could mitigate APA for the oblique tubes of response of long axial FOV systems subjected to larger APA blurring. This last observation is of particular interest as it suggests that the nonstationary nature of spatial resolution in PET imaging can be further mitigated when such TOF precision is achieved.

Indexed as

Acollinearity of the annihilation photonspositron emission tomographysimulations for imaging and therapy spatial resolutiontime-of-flighttomographic image reconstruction

Identifiers

PMID41816633
PMCPMC12975006

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.