Evidence map›Paper›PMID 41814903›Full record

ArticleSe pu = Chinese journal of chromatography2026

[Determination of vitamin A and vitamin E in human tear by liquid chromatography-tandem mass spectrometry and analysis of their relationship with dry eye].

Bao-Bin Luo, Jing-Ran Jiao, Jing Bai, Xiang-Yi Liu

Abstract readEnglish Abstract
In one paragraph

Article in Se pu = Chinese journal of chromatography, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Bao-Bin LuoBeijing Tongren Hospital,Capital Medical University,Beijing 100730,China.
Jing-Ran JiaoBeijing Youan Hospital,Capital Medical University,Beijing 100069,China.
Jing BaiBeijing Tongren Hospital,Capital Medical University,Beijing 100730,China.
Xiang-Yi LiuBeijing Tongren Hospital,Capital Medical University,Beijing 100730,China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dry eye is characterized as a multifactorial disorder affecting the tear film and ocular surface, leading to symptoms of discomfort and visual disturbances, with the potential for ocular surface damage. It is among the most prevalent ocular surface disorders, with an estimated prevalence ranging from 5.0% to 50.0%, and an overall prevalence between 21.0% and 50.4% in China. Despite its high global prevalence, the fundamental mechanisms underlying the pathology of dry eye remain largely unexplored. Vitamins are crucial for maintaining ocular surface homeostasis, with vitamins A and E being physiologically present and essential for cell differentiation, development, and proper function. Deficiencies in these vitamins are frequently associated with dry eye, and systemic supplementation has been shown to benefit patients with low vitamin intake. Vitamins A and E may have potential clinical predictive value for the diagnosis and treatment of dry eye. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to simultaneously measure the concentrations of vitamins A and E in human tears. A Phenomenex Kinetex C18 column was employed for gradient elution at a flow rate of 0.4 mL/min. The mobile phase A consisted of a 0.1% formic acid aqueous solution, while mobile phase B comprised a 2 mmol/L ammonium acetate and 0.1% formic acid methanol solution. Positive atmospheric pressure chemical ionization in multiple reaction monitoring mode was utilized for MS/MS detection. The analytical method for vitamin A demonstrated a validated linear range of 5.00-300.00 ng/mL, with a limit of detection at 2.00 ng/mL. The spiked recoveries were between 98.3% and 104.7%, and intra- and inter-day precision ranged from 1.2% to 7.0%. Similarly, the method for vitamin E exhibited a validated linear range of 25.00-1 000.00 ng/mL, with a limit of detection at 6.00 ng/mL. The spiked recoveries ranged from 97.9% to 105.5%, and intra- and inter-day precision varied between 3.0% and 5.7%. Tear samples from five patients with dry eye and nine healthy volunteers were analyzed using this method. In the dry eye group, the average concentrations of vitamin A and vitamin E were 9.60 (5.13-12.54) ng/mL and 42.00 (31.75-128.00) ng/mL, respectively. In the healthy group, the average concentrations of vitamin A and vitamin E were 18.10 (12.46-21.69) ng/mL and 211.00 (181.00-459.75) ng/mL, respectively. Statistical differences in vitamin A and vitamin E levels between the dry eye group and the healthy group were identified using the Wilcoxon Mann-Whitney test (

Indexed as

Dry Eye SyndromesLiquid Chromatography-Mass SpectrometryTandem Mass SpectrometryTearsVitamin AVitamin EFemaleHumansVitamin AVitamin Edry eyeliquid chromatography-tandem mass spectrometry (LC-MS/MS)tearsvitamin Avitamin E

Identifiers

PMID41814903
PMCPMC12980511

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.