ArticleIndian pacing and electrophysiology journal
Novel use of an atrial Aveir AR pacemaker implanted in the right ventricle for a pediatric patient with prolonged sinus pause.
Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Leadless pacemakers offer an attractive alternative to transvenous systems in children but are limited by vascular size, cardiac chamber dimensions, and device-specific characteristics. We describe the first implantation of an atrial Aveir AR leadless pacemaker in the right ventricle of a pediatric patient using a superior venous approach. A 7-year-old, 23.7-kg girl presented with recurrent syncope and was found to have an 8.7-s sinus pause on ambulatory monitoring consistent with sinus node dysfunction. Pre-procedural echocardiography and ultrasound assessment demonstrated relatively small atrial dimensions and identified the right internal jugular vein (1 cm) as the largest available central vessel compared with the femoral and left internal jugular veins. To optimize catheter maneuverability and accommodate the 27-Fr delivery sheath, a right internal jugular approach was selected. The Aveir AR device was advanced across the tricuspid valve and fixed to the mid-right ventricular septum on the first attempt, with stable sensing and capture parameters and no periprocedural complications (threshold 0.5 V at 0.2 ms, impedance 400 Ω, R-wave 5.9 mV). The patient was discharged within 24 hours and remained asymptomatic with preserved device function on one month follow-up, with threshold 0.75 V at 0.2 ms, impedance 410 Ω, R-wave 8.3 mV, and with <1% pacing, predicted longevity at 15.9 years. This case illustrates that superior venous access can facilitate safe ventricular deployment of an Aveir AR leadless pacemaker in select pediatric patients with sinus pauses.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.