Evidence map›Paper›PMID 41811908›Full record

ArticlePLOS global public health2026

Sensitivity and specificity of Dried Blood Spot and Plasma Separation Card samples for Hepatitis C Virus RNA Testing.

Agnes Malobela, Marie Amougou-Atsama, Panagiotis Iliopoulos, Jean-Claude Mugisha, Nino Berishvili, Manana Sologashvili, Emmanuel Fajardo, Francois Lamoury, Aurélien Macé, Maxwell Chirehwa and 8 more

Abstract read
In one paragraph

Article in PLOS global public health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Agnes MalobelaFIND, the global alliance for diagnostics, Geneva, Switzerland.ORCID https://orcid.org/0009-0009-8602-3011
Marie Amougou-AtsamaCentre Pasteur du Cameroun, Yaoundé, Cameroon.
Panagiotis IliopoulosHellenic Scientific Society for the Study of AIDS, Sexually Transmitted and Emerging Diseases, Athens, Greece.
Jean-Claude MugishaRwanda Military Hospital, Kigali, Rwanda.
Nino BerishviliNational Center for Disease Control and Public Health, Tbilisi, Georgia.
Manana SologashviliHepa Plus, Tbilisi, Georgia.
Emmanuel FajardoFIND, the global alliance for diagnostics, Geneva, Switzerland.
Francois LamouryFIND, the global alliance for diagnostics, Geneva, Switzerland.
Aurélien MacéFIND, the global alliance for diagnostics, Geneva, Switzerland.
Maxwell ChirehwaUniversity of Cape Town, Cape Town, South Africa.
Richard NjouomCentre Pasteur du Cameroun, Yaoundé, Cameroon.ORCID https://orcid.org/0000-0003-3112-6370
Angelos HatzakisHellenic Scientific Society for the Study of AIDS, Sexually Transmitted and Emerging Diseases, Athens, Greece.
Jules KabahiziRwanda Military Hospital, Kigali, Rwanda.
Claude Mambo MuvunyiRwanda Biomedical Center, Kigali, Rwanda.
Penny BuxtonNational Reference Laboratory, Victoria, Australia.
Sadaf MohiuddinNational Reference Laboratory, Victoria, Australia.
Maia AlkhazashviliNational Center for Disease Control and Public Health, Tbilisi, Georgia.
Elena Ivanova ReipoldFIND, the global alliance for diagnostics, Geneva, Switzerland.ORCID https://orcid.org/0000-0003-2872-5161

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dried blood spots (DBS) and plasma separation cards (PSC) have the potential to improve access to hepatitis C virus (HCV) testing. This multicenter study evaluated the performance of two HCV RNA assay platforms using capillary or venous DBS and PSC. Participants were enrolled in Cameroon, Rwanda, Georgia, and Greece. DBS and PSC prepared from capillary and venous blood samples were collected from three target populations; individuals at risk of HCV infection, persons living with HCV, and individuals previously treated for HCV. The diagnostic accuracy of DBS and PSC for detecting HCV RNA was assessed using the cobas HCV nucleic assay on the cobas 4800 and cobas 6800 platforms (Roche), with plasma samples tested using these platforms serving as the reference standard. A total of 936 participants were enrolled. Capillary, venous DBS and venous PSC demonstrated high diagnostic accuracy. Sensitivity and specificity were 97.2% (95% CI: 95.2-98.3) and 88.6% (95%CI: 85.4 -91.2) for capillary DBS, 96.1% (95%CI: 93.9 -97.5) and 87.8% (95%CI: 85.4 -90.4) for venous DBS and 95.2% (95%CI: 92.8 -96.8) and 99.6% (95%CI: 98.5 -99.9) for venous PSC, on the cobas 4800. The cobas 6800 platform had a sensitivity and specificity of 97.3% (95%CI: 95.4 -98.5) and 95.9% (95%CI: 93.7 -97.3) on venous DBS, 96.7% (95%CI: 94.6 -98.0) and 99.8% (95%CI: 98.8 - 100) on venous PSC, and 96.9% (95%CI: 94.8 -98.1) and 99.8% (95%CI: 98.8 - 100) on capillary PSC. The diagnostic accuracy of capillary and venous DBS and PSC for detecting HCV RNA was high on the two platforms evaluated. This study demonstrates that DBS and PSC sample types can be an alternative to plasma to screen for HCV infection, thus facilitating access to testing. IMPORTANCE: Although the use of point-of-care rapid antibody tests for hepatitis C virus (HCV) is increasing, people who test positive must still undergo a confirmatory test before receiving treatment. Confirmatory testing for HCV RNA can be performed using plasma, serum, or capillary whole blood, depending on the available diagnostic platforms and testing algorithms. Plasma samples are more commonly used; however, their collection, storage, transport, and handling can pose significant challenges in low-resource settings. To improve access to HCV testing, there is a need for alternative sample types. Blood samples dried on filter paper cards (dried blood spots, or DBS) can be collected at the community level, have low biohazard risk, can withstand exposure to ambient temperatures, and are easily stored and shipped. Plasma Separation Cards (PSC), which collect plasma rather than whole blood, have similar properties. This study demonstrated that the diagnostic accuracy of DBS and PSC for detecting HCV RNA using the Roche cobas 4800 and 6800 platforms was high, confirming that they could be viable alternatives to plasma sampling for HCV testing.

Identifiers

PMID41811908
PMCPMC12978484

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.