Evidence map›Paper›PMID 41811318›Full record

ArticleJAMA network open2026

Suspended Lead Suits and Radiation Exposure in Interventional Echocardiographers.

David A McNamara, Jeffrey M Decker, Michael W McNamara, Mohamad A Kenaan, David M Cameron, Stacie VanOosterhout, Jessica L Parker, Ryan D Madder

Abstract read
In one paragraph

Article in JAMA network open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

David A McNamaraFrederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan.
Jeffrey M DeckerFrederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan.
Michael W McNamaraFrederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan.
Mohamad A KenaanFrederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan.
David M CameronFrederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan.
Stacie VanOosterhoutCorewell Health Research Institute, Corewell Health, Grand Rapids, Michigan.
Jessica L ParkerCorewell Health Research Institute, Corewell Health, Grand Rapids, Michigan.
Ryan D MadderFrederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Percutaneous left atrial appendage occlusion (LAAO) is frequently performed with an interventional echocardiographer (IE) in close proximity to the patient and radiation source, increasing the risk for occupational radiation exposure. Yet optimal radiation shielding methods for IEs remain unknown. Objective: To assess whether using a suspended lead suit reduces IE radiation dose compared with traditional lead apron shielding during LAAO procedures. Design, Setting, and Participants: In this blinded cross-sectional study, IE radiation exposure data were prospectively collected during all LAAO procedures conducted for adults at a single quaternary care center from February 21 to August 22, 2023. Head-level dosimeters were worn by IEs who were using suspended lead suits during sequential LAAO procedures conducted at the center. Exposures: Use of a suspended lead suit or traditional lead apron radiation protection device. Main Outcomes and Measures: The primary outcome was measured personal dose equivalents at head level to IEs per case using real-time radiation dosimeters. Dosimeter-derived physician radiation doses and procedural radiation (dose area product) were compared with a control group of 30 sequential historical LAAO cases performed with IEs wearing traditional lead aprons from July 1, 2016, to January 31, 2018. Results: Overall, 125 patients (mean [SD] age, 78 [8] years; 77 [61.6%] male) were included. Among 95 cases in which IEs used suspended lead suits, the median (IQR) radiation dose was 0.0 (0.0-0.3) μSv, which was significantly lower than 30 cases in which IEs wore traditional lead aprons (median [IQR], 10.6 [5.8-24.1] μSv; P < .001). Radiation doses were undetectable in 60% of IEs (57of 95) using suspended lead suits compared with 0% of IEs (0 of 30) using traditional lead aprons (P < .001). Radiation doses of at least 20 μSv were observed in 0 of 95 cases (0%) with suspended lead suits vs 9 of 30 cases (30%) with traditional lead aprons (P < .001). Similar associations were noted in exploratory analyses adjusting IE radiation doses for procedural dose area product (mean [IQR], 0.0 [0.0-0.0] μSv/Gy × cm2) for suspended lead suits vs traditional lead aprons (mean [IQR], 0.6 [0.3-1.0] μSv/Gy × cm2; P < .001). Conclusions and Relevance: In this cross-sectional study, the use of suspended lead suits was associated with large reductions in head-level radiation doses to IEs compared with the use of traditional lead aprons during LAAO cases. These findings have important ramifications for the risk of occupational radiation exposure to IEs and potential shielding mechanisms during structural heart interventions.

Indexed as

EchocardiographyOccupational ExposureProtective ClothingRadiation ExposureRadiation ProtectionAgedCross-Sectional StudiesFemaleHumansLeadLeft Atrial Appendage ClosureMaleMiddle AgedProspective StudiesRadiation DosageLead

Identifiers

PMID41811318
PMCPMC12980244

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390