Evidence map›Paper›PMID 41809620›Full record

ArticleBreast cancer (Dove Medical Press)2026

A Brand-New Drainage Fluid Predictor, ICAM-1 for Implant Loss After the Immediate Reconstruction of Breast.

Chenyang He, Yezhen Jiang, Renyang Zhao, Jia Liu, Haiying Yang, Rongqiang Zhang, Yang Zhao

Abstract read
In one paragraph

Article in Breast cancer (Dove Medical Press), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Chenyang He *The Comprehensive Breast Care Center, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, People's Republic of China.
Yezhen Jiang *Genertec Universal Xi'an Beihuan Hospital, Xi'an, Shaanxi Province, People's Republic of China.
Renyang Zhao *The Comprehensive Breast Care Center, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, People's Republic of China.
Jia LiuThe Comprehensive Breast Care Center, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, People's Republic of China.
Haiying YangThe Comprehensive Breast Care Center, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, People's Republic of China.
Rongqiang ZhangSchool of Public Health, Shaanxi University of Chinese Medicine, Xianyang, Shaanxi Province, People's Republic of China.
Yang ZhaoThe Comprehensive Breast Care Center, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, People's Republic of China.ORCID 0009-0002-4334-1107

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Nearly 40% of breast cancer patients are ineligible for breast-conserving surgery. Immediate implant-based breast reconstruction is a preferred option for these patients. The most severe complication of this procedure is implant loss. Currently, there are no cytokines available to predict implant failure. To identify a drainage biomarker predicting implant loss and evaluate whether dexamethasone irrigation in high-risk cases is associated with reduced implant failure, we designed this study. Methods: A retrospective cohort study was conducted between December 2022 and March 2024, patients undergoing mastectomy with immediate implant-based reconstruction were recruited. We applied protein microarray to analyze cytokines in the drainage fluid from the implant pocket to identify cytokines associated with implant failure. Results: We initially selected 3 patients with implant failure and 3 with successful implant outcomes as the cohort for protein microarray analysis. Drainage fluid samples were collected and analyzed at 3 time points: 24 hours postoperatively, at drainage removal and at the onset of implant failure. This analysis identified intercellular adhesion molecule-1 (ICAM-1) as a candidate marker that meets the criteria for predicting implant failure. Subsequently, we validated ICAM-1's predictive potential in a separate cohort of breast cancer patients who underwent immediate implant-based breast reconstruction between December 2022 and March 2024. Our results demonstrated that ICAM-1 levels in drainage fluid at the time of drainage removal effectively predicted implant failure following immediate breast reconstruction for breast cancer. Additionally, a retrospective analysis revealed that intracavitary irrigation with dexamethasone significantly reduced ICAM-1 level in the drainage fluid and reversed impending implant failure. Conclusion: The data confirmed the potential of ICAM-1 as a predictive factor for breast implant failure. Intracavitary irrigation with dexamethasone was effective to prevent implant loss.

Indexed as

ICAM-1immediate breast reconstructionimplant losspredictive factor

Identifiers

PMID41809620
PMCPMC12970029

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.