ArticleIEEE transactions on instrumentation and measurement2026

Wearable Ultrasound Sensing with Dual Arrays and Machine Learning for Real-Time Tremor Characterization and Antagonist Muscle Monitoring.

Xiangming Xue, Sunho Moon, Vidisha Ganesh, Qianqian Cai, Yu Chu, Ella Schropp, Daniel Roque, Tanya P Garcia, Nitin Sharma, Xiaoning Jiang

Abstract read
In one paragraph

Article in IEEE transactions on instrumentation and measurement, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Ultrasound-Informed State Estimation of Wrist Tremor Dynamics via Koopman Operator for Personalized Sensory Peripheral Nerve Stimulation.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Xiangming XueLampe Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Sunho MoonDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA.
Vidisha GaneshLampe Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Qianqian CaiDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA.
Yu ChuDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA.
Ella SchroppLampe Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Daniel RoqueDivision of Movement Disorders, Division of Movement Disorders, Department of Neurology, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
Tanya P GarciaDepartment of Biostatistics, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
Nitin SharmaLampe Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Xiaoning JiangDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA.

Funding

Data-driven Modeling and Ultrasound-based Control of Afferent Nerve Stimulation for Tremor SuppressionR21EB032059 · NIBIB · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI SHARMA, NITIN · 2021 to 2023
$526k
NIBIB NIH HHS R21 EB032059
6 · The paper itself

Abstract

Precise and time-efficient sensing of tremor dynamics is essential for developing personalized, adaptive stimulation strategies for movement disorders such as Parkinson's Disease (PD) and Essential Tremor (ET). Existing modalities-such as inertial measurement units (IMUs) and surface electromyography (EMG)-lack muscle specificity and are prone to stimulation artifacts. To address these limitations, we fabricated and applied a Wearable Ultrasound Sensing (WUS) system, featuring dual flexible 64- element transducer arrays with center frequency of 6 MHz conformed over the flexor carpi radialis (FCR) and extensor carpi radialis (ECR) muscles for simultaneous antagonist muscle monitoring. A machine learning (ML) pipeline was introduced to estimate tissue displacement (TD) from raw ultrasound signals. Across three participants and multiple trials, the WUS system achieved tremor frequency detection within 10 % variation relative to commercial B-mode and IMU sensors, and met statistical equivalence thresholds based on two one-sided test (TOST) analysis. The TD estimation models demonstrated high predictive accuracy, with overall Pearson correlation coefficients between predicted and actual values ranging from 0.88 to 0.97, normalized RMSE values below 10 %, and offline model building times under 800 seconds. Compared to classical B-mode speckle tracking, the proposed WUS-ML pipeline reduced offline model building time by 75 % (from 3095 sec to 792 sec). In real-time performance tests, it reduced frame-level latency from 3700 ms to 17 ms and achieved effective processing rates exceeding 50 Hz, well above the Nyquist threshold for tremor analysis. These results demonstrate the feasibility of dual-array wearable ultrasound for accurate, low-latency tremor tracking and lay the groundwork for future closed-loop afferent stimulation systems in both clinical and at-home environments.

Indexed as

Afferent stimulationBiomedical signal processingMachine learningTremor frequency estimationWearable ultrasound

Identifiers

PMID41809115
PMCPMC12971078

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.