Evidence map›Paper›PMID 41808182›Full record

ArticlePlant methods2026

An efficient clear-native PAGE-based workflow for cryo-electron microscopy sample preparation of large protein complexes.

Zitong Yang, Shinsa Kameo, Soichiro Seki, Genji Kurisu, Ryouichi Tanaka, Akihiro Kawamoto, Atsushi Takabayashi

Abstract read
In one paragraph

Article in Plant methods, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zitong YangInstitute of Low Temperature Science, Hokkaido University, N19 W8 Kita-Ku, Sapporo, 060-0819, Japan.
Shinsa KameoInstitute of Low Temperature Science, Hokkaido University, N19 W8 Kita-Ku, Sapporo, 060-0819, Japan.
Soichiro SekiInstitute for Protein Research, The University of Osaka, 3-2 Yamadaoka, Suita, 565-0871, Osaka, Japan.
Genji KurisuInstitute for Protein Research, The University of Osaka, 3-2 Yamadaoka, Suita, 565-0871, Osaka, Japan.
Ryouichi TanakaInstitute of Low Temperature Science, Hokkaido University, N19 W8 Kita-Ku, Sapporo, 060-0819, Japan.
Akihiro KawamotoInstitute for Protein Research, The University of Osaka, 3-2 Yamadaoka, Suita, 565-0871, Osaka, Japan. kawamoto@protein.osaka-u.ac.jp.
Atsushi TakabayashiInstitute of Low Temperature Science, Hokkaido University, N19 W8 Kita-Ku, Sapporo, 060-0819, Japan. takabayashi@lowtem.hokudai.ac.jp.

Funding

Japan Society for the Promotion of Science 23H04958Japan Society for the Promotion of Science 23H04960Japan Society for the Promotion of Science 24K09496
6 · The paper itself

Abstract

backgroundCryo-electron microscopy (cryo-EM) has revolutionized protein research by enabling high-resolution structural analysis. However, preparing ultra-large protein complexes (e.g., > 700 kDa) for cryo-EM remains challenging, as it requires preserving both structural integrity and the native state. Conventional isolation methods, such as sucrose density gradient centrifugation, require large sample volumes and provide limited separation resolution. In contrast, native PAGE offers higher resolution; however, no established method exists for extracting protein complexes from gels followed by further purification to achieve high purity. Consequently, no standardized native PAGE-based protocol for cryo-EM sample preparation avoids multiple purification steps. Hence, we aimed to develop a rapid and efficient cryo-EM protein sample preparation method using electroelution with an optimized buffer system that preserves complex integrity to recover target protein complexes after sodium deoxycholate (DOC)-based clear-native PAGE (CN-PAGE).

resultsWe developed an agarose-acrylamide composite gel, which is simpler to prepare and mechanically more robust than conventional linear-gradient acrylamide gels commonly used for CN-PAGE, facilitating precise band excision for efficient electroelution. Cryo-EM structural analysis of the photosystem I-light-harvesting complex I (PSI-LHCI) supercomplex from Arabidopsis thaliana achieved high resolution (2.18 Å) after electroelution from this gel, requiring only buffer exchange by ultrafiltration to remove DOC before grid preparation, without additional chromatographic purification. This finding suggests that DOC may be the main inhibitor of successful grid preparation.

conclusionOur results demonstrate the potential of this method for isolating large protein complexes from small sample volumes for cryo-EM structural analysis. This approach may expand the scope of cryo-EM targets to include some challenging systems previously hindered by purification difficulties.

Indexed as

Clear-native PAGECryo-EMElectroelutionPhotosystemProtein complex

Identifiers

PMID41808182
PMCPMC13088791

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.