Evidence map›Paper›PMID 41808117›Full record

ArticlePatient safety in surgery2026

Inadvertent guidewire retention after radial artery cannulation: report of two cases and safety lessons for vascular access practice.

Leopoldo Muniz da Silva, Rafael Souza Fava Nersessian, Saullo Queiroz Silveira, Helidea de Oliveira Lima, Glenio B Mizubuti

Abstract read
In one paragraph

Article in Patient safety in surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Leopoldo Muniz da Silva *São Luiz Hospital (Rede D'Or), São Paulo, SP, Brazil. Leopoldo_muniz@hotmail.com.ORCID http://orcid.org/0000-0003-4703-0832
Rafael Souza Fava Nersessian *São Luiz Hospital (Rede D'Or), São Paulo, SP, Brazil.
Saullo Queiroz SilveiraSão Luiz Hospital (Rede D'Or), São Paulo, SP, Brazil.
Helidea de Oliveira LimaIDOR - D'Or Institute for Research and Education, São Paulo, Brazil.
Glenio B MizubutiDepartment of Anesthesiology and Perioperative Medicine, Queen's University, Kingston, ON, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInadvertent guidewire retention is an uncommon but potentially serious complication most often described in the context of central venous catheterization, and reports involving arterial access are exceptionally rare. This report describes two cases of inadvertent guidewire retention following radial artery cannulation performed using the Seldinger technique for intraoperative hemodynamic monitoring. CASE PRESENTATION: In both cases, arterial cannulation was indicated because of complex (and possibly prolonged) surgical procedures with a risk of clinically significant blood loss, thereby necessitating continuous beat-to-beat arterial pressure monitoring. The presumed embolization mechanism involved advancement of the catheter while the pre-attached proximal cap remained in place, thereby preventing the guidewire from exiting proximally and ultimately leading to intravascular displacement of the wire. In the first case, the event remained unrecognized until the patient developed forearm pain, reduced radial and ulnar pulses, and sensory changes to the affected upper extremity several weeks postoperatively. Imaging revealed a retained guidewire extending from the radial artery to the axillary artery, requiring surgical intervention for retrieval. In the second case, the inadvertently retained guidewire was found incidentally on a routine chest radiograph eighteen days postoperatively.

conclusionsThese cases illustrate that guidewire retention, albeit rare, can occur during arterial cannulation by the Seldinger technique and shares the same human-factor vulnerabilities long recognized in central venous access-related guidewire retention, including distraction, incomplete preparation and loss of wire control. In response, several system-level safety measures were implemented, including explicit “wire in hand” confirmation before catheter advancement, the use of wire length markers, mandatory removal of manufacturer attached catheter caps prior to insertion, optional sterile forceps control of the guidewire, multidisciplinary verification, and mandatory documentation of guidewire retrieval. These events reinforce the need for robust safety barriers across all procedures using the Seldinger technique to prevent guidewire retention and enhance procedural safety.

Indexed as

Case reportsCatheterizationGuidewiresPatient safetyRadial arterySeldinger technique

Identifiers

PMID41808117
PMCPMC13088528

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390