ArticleScientific reports2026
Design of a tube lens with a focus tunable lens for optical inspection systems.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Optical inspection systems use large numerical apertures (NAs) to achieve high resolution. However, as the NA increases, the depth of field decreases significantly, causing images to blur easily with slight object shifts. Conventional methods maintain focus by mechanically moving the entire lens or specific lens groups. However, these methods increase the system volume, require high-performance motors, and necessitate precise inertial control when the lens group mass is substantial. In this study, we propose a novel tube lens design that integrates a focus tunable lens (FTL), which electronically adjusts its curvature without requiring mechanical movement. We precisely calculated the required curvature radius of the FTL for various object distances and performed optical simulations to verify the system performance before fabrication. The developed tube lens has a focal length of 300 mm and is combined with objective lenses featuring focal lengths of 30 and 60 mm. This enables magnifications of 10X and 5X, respectively. Simulation results confirmed stable image positions for object shifts of ± 50 μm and ± 0.36 mm at 10X and 5X magnifications, respectively, while maintaining diffraction-limited resolution and near-zero distortion aberration. These findings demonstrate that FTL-based focus control is highly suitable for high-precision inspection and imaging applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.