Evidence map›Paper›PMID 41807326›Full record

ArticleMedical physics2026

Plaque-adaptive flexible film dosimetry system for Ru-106 plaque brachytherapy commissioning and quality assurance.

Jin Dong Cho, Hojae Kim, Dong Wook Kim, Heerim Nam, Jin Sung Kim, Jung-In Kim

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jin Dong ChoDepartment of Radiation Oncology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-1914-8163
Hojae KimDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-5616-8887
Dong Wook KimDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-5819-9783
Heerim NamDepartment of Radiation Oncology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-1118-8200
Jin Sung KimDepartment of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-1415-6471
Jung-In KimDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-0305-5969

Funding

Korea Institute for Advancement of Technology P0026103Ministry of Trade, Industry and Energy
6 · The paper itself

Abstract

backgroundRuthenium-106 (Ru-106) plaque brachytherapy is an established treatment modality for choroidal melanoma that delivers localized beta radiation while sparing surrounding ocular structures. It is widely used in Europe and parts of Asia, whereas COMS Iodine-125 and Palladium-103 plaques remain the standard in the United States. However, its concave geometry presents challenges for accurate dose verification, as conventional flat dosimeters are ill-suited for use during commissioning and quality assurance (QA). PURPOSE: This study aimed to assess the feasibility and dosimetric accuracy of a plaque-adaptive flexible film dosimeter (PFD) for planar and central axis (CAX) dose measurements in Ru-106 plaque brachytherapy.

methodsThe PFD consisted of an active layer of lithium salt of pentacosa-10,12-diynoic acid (LiPCDA) enclosed between upper and lower silicone sheets. The flexible film was shaped to conform to the curvature of the Ru-106 plaques and mounted within a dual-layer film holder. A 3D-printed QA tool was used for reproducible positioning. Dose measurements were performed at depths of 1 and 3 mm for CCA, COB, and CIB plaque types using a dual-film configuration. Planar dose distributions were assessed at 33 manufacturer-certified reference points at a 1 mm depth. CAX dose profiles were independently acquired using a microDiamond detector in a water phantom. All measurements were compared with manufacturer-certified reference data. Calibration curves were established based on optical density and dose uncertainties were analyzed.

resultsThe dose ratio between 1 and 3 mm depths measured with the PFD differed by -0.2% to 0.4% from the reference data across all plaque types. Planar dose measurements at 33 points yielded a mean difference of 3.0%  ±  2.0% from reference values. In the high-dose central region, the mean differences for CCA, COB, and CIB were 2.1%  ±  0.8%, 2.1%  ±  0.8%, and 2.2%  ±  0.7%, respectively. CAX dose profiles measured with a microDiamond detector differed by 0.89%  ±  0.58%. Total dose uncertainty ranged from 4.43% at 0.3 Gy to 4.19% at 2.4 Gy.

conclusionsThe PFD enabled accurate and high-resolution dose measurements on the curved surfaces of Ru-106 plaques. Both planar and CAX measurements demonstrated strong agreement with manufacturer-certified reference data across all plaque types. This system offers a practical and reproducible solution for commissioning and QA in Ru-106 plaque brachytherapy, supporting its clinical integration for choroidal melanoma treatment.

Indexed as

BrachytherapyFilm DosimetryQuality Assurance, Health CareRuthenium RadioisotopesQuality ControlRadiotherapy DosageRuthenium-106Ruthenium Radioisotopeseye plaque brachytherapyfilm dosimetryquality assurance

Identifiers

PMID41807326
PMCPMC12975687

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.