Evidence map›Paper›PMID 41806149›Full record

ArticleHernia : the journal of hernias and abdominal wall surgery2026

Concurrent validity and agreement of the HerniaCare Lab device for abdominal wall strength assessment.

José Luis Gil Delgado, Carlos Rangel Cascajosa, Alejandro Sánchez Arteaga, Luis Tallón Aguilar, Borja Sañudo Corrales

Abstract readValidation StudyComparative Study
In one paragraph

Article in Hernia : the journal of hernias and abdominal wall surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

José Luis Gil DelgadoDepartment of Physical Education and Sports, University of Seville, Seville, Spain.
Carlos Rangel CascajosaDepartment of Physical Education and Sports, University of Seville, Seville, Spain.
Alejandro Sánchez ArteagaDepartment of General Surgery, Hospital Universitario Virgen del Rocío, Avda. Manuel Siurot S/N, Seville, 41013, Spain. Alejandros.arteaga@gmail.com.ORCID http://orcid.org/0000-0002-0875-7185
Luis Tallón AguilarDepartment of General Surgery, Hospital Universitario Virgen del Rocío, Avda. Manuel Siurot S/N, Seville, 41013, Spain.
Borja Sañudo CorralesDepartment of Physical Education and Sports, University of Seville, Seville, Spain. bsancor@us.es.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCurrently, no standardized, low-cost, and portable method is available for assessing abdominal wall strength in patients with incisional hernias, addressing the limitations of traditional dynamometry.

methodsThis cross-sectional validation study compared the HerniaCare Lab device performance with the Activforce 2 hand-held dynamometer in92 adults diagnosed with abdominal wall hernias. Isometric trunk flexion strength was measured under identical conditions, and agreement between devices was analyzed using non-parametric tests, correlation, and concordance statistics.

resultsThe HerniaCare Lab showed systematically higher strength values than the Activforce 2 (mean difference = + 22.3 N, p < 0.001) but demonstrated a very strong positive correlation (ρ = 0.95, p < 0.001) and good concordance (CCC = 0.89). Bland–Altman analysis revealed a mean bias of + 24.9 N with 95% limits of agreement from − 17.7 to+ 67.5 N, and a slight proportional bias at higher force levels.

conclusionDespite predictable overestimation, the HerniaCare Lab exhibits strong concurrent validity and good agreement with an established reference device, supporting its potential clinical utility for objective, reproducible, and accessible assessment of abdominal wall strength in surgical populations.

Indexed as

Abdominal MusclesAbdominal WallIncisional HerniaMuscle StrengthMuscle Strength DynamometerAdultCross-Sectional StudiesFemaleHernia, AbdominalHumansReproducibility of ResultsAbdominal wall herniaDevice validationHand-held dynamometryMuscle strength assessment

Identifiers

PMID41806149
PMCPMC12975811

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked