Evidence map›Paper›PMID 41805896›Full record

ArticleThe ultrasound journal2026

Feasibility of measuring left ventricular outflow tract velocity time integral as a predictor for stroke volume in pregnant women in labor.

Mohamed Eissa, George Dumitrascu, Elizabeth Miller, Jennifer Racine, Victoria Postnikova, Wesley Rajaleelan, Wesley Edwards, Hesham Talab, Daniel McIsaac

Abstract read
In one paragraph

Article in The ultrasound journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mohamed EissaDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada; Ottawa Hospital Research Institute, Ottawa, ON, Canada; Ain Shams University, Cairo, Egypt.ORCID 0000-0003-1014-6866
George DumitrascuDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada.
Elizabeth MillerDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada.
Jennifer RacineDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada.
Victoria PostnikovaDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada.
Wesley RajaleelanDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada.
Wesley EdwardsDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada.
Hesham TalabDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada; Ain Shams University, Cairo, Egypt.
Daniel McIsaacDepartment of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada; The Ottawa Hospital, Ottawa, ON, Canada; Ottawa Hospital Research Institute, Ottawa, ON, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPregnancy is a time of significant hemodynamic changes. Maintaining adequate cardiac output (CO) and uteroplacental perfusion is a priority in parturients, for favorable maternal-fetal outcomes. Blood pressure is commonly used as a surrogate for CO, although it may poorly correlate with stroke volume (SV) and CO in some cases. An alternative approach is SV estimation using transthoracic echocardiography (TTE) based on the velocity-time integral (VTI) of the left ventricular outflow tract (LVOT). Although VTI has been validated as a tool to estimate SV and CO in acute care contexts, its feasibility and utility in obstetric anesthesia remain unexplored. Therefore, the objective of this study is to evaluate the feasibility and reproducibility of LVOT VTI measurements in parturients during labor.

methodsFollowing research ethics board approval, 55 full term pregnant female patients with a singleton pregnancy were recruited. TTE was used to calculate the LVOT VTI for each patient by the same anesthesiologist twice. Feasibility of obtaining the LVOT VTI was evaluated using time for image acquisition and the 3-Point Likert Scale for Imaging Quality. Intraclass correlation coefficients (ICC) were used to estimate intra-rater reliability.

resultsLVOT VTI was obtained for all participants on both attempts. Mean time needed to obtain measurements was 63.7 seconds (95%CI 56.5 to 70.8) on the 1st attempt and 44.2 seconds (95%CI 38.7 to 49.8) on the 2nd attempt. Eighty-one (73.6%) images were rated as optimal, 29 (26.3%) were rated as suboptimal. Intra-rater reliability was excellent (ICC was 0.94 (95%CI 0.92 to 0.95).

conclusionIn singleton parturients, LVOT VTI measurements can be routinely obtained in a timely fashion with excellent intra-rater reliability during labor. These results support the feasibility of LVOT VTI to estimate and trend SV.

Identifiers

PMID41805896
PMCPMC13320601

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.