Evidence map›Paper›PMID 41805779›Full record

ArticlePloS one2026

Comparison of glucose concentrations in simultaneously collected plasma and serum samples from outpatients in a routine laboratory setting.

Robert Müller, Diethard Müller, Dietmar Plonné

Abstract readComparative Study
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Robert MüllerMVZ Labor Ravensburg SE and Co., eGbR, Limbach Gruppe, Ravensburg, Germany.
Diethard MüllerMVZ Labor Ravensburg SE and Co., eGbR, Limbach Gruppe, Ravensburg, Germany.
Dietmar PlonnéMVZ Labor Ravensburg SE and Co., eGbR, Limbach Gruppe, Ravensburg, Germany.ORCID https://orcid.org/0009-0002-5527-7317

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAlthough international and national German guidelines recommend measuring glucose in venous plasma, serum remains the most commonly used sample type for glucose measurement in routine outpatient settings in Germany. The aim of the study was to compare glucose concentrations in simultaneously collected serum and plasma samples from outpatients under routine conditions, and to assess whether any observed differences could lead to divergent diagnostic outcomes for diabetes mellitus.

methodsBetween 03/01/2022 and 20/12/2024, a total of 27,864 simultaneously collected sodium fluoride plasma (NaF plasma) and serum sample pairs were submitted by 200 different medical practices to MVZ Labor Ravensburg for glucose measurement. Serum samples, all containing separator gel, were centrifuged at the medical practice after complete coagulation. In contrast, NaF plasma samples were transported uncentrifuged. Upon arrival at the laboratory, all samples were centrifuged immediately and analyzed within two hours. The median of the differences between serum and plasma glucose was calculated for each quintile of the mean glucose concentration. A contingency table was used to analyze the classification outcomes based on plasma and serum glucose concentrations.

resultsIn the concentration range above 100 mg/dL, the difference between serum and plasma glucose levels was minimal (4th quintile: 0.54 mg/dL; 5th quintile: 1.13 mg/dL). Below 100 mg/dL, the difference increased linearly with decreasing glucose concentration (3rd quintile: -1.69 mg/dL; 2nd quintile: -5.20 mg/dL; 1st quintile: -11.05 mg/dL). Using 126 mg/dL as the glucose cutoff, positive and negative diabetes classifications from NaF plasma and serum glucose agreed in 97.8% of cases. Overall, only 0.3% more cases of diabetes mellitus were classified based on NaF plasma glucose compared to serum glucose.

conclusionsIn real-world outpatient settings, glucose measurement in on-site centrifuged serum with separator gel does not appear to present a clinically relevant disadvantage for diabetes mellitus screening compared to on-site uncentrifuged NaF plasma. However, neither serum nor non-acidified NaF plasma ensures complete inhibition of in vitro glycolysis and must therefore be regarded as suboptimal for definitive diagnostic purposes.

Indexed as

Blood GlucoseDiabetes MellitusPlasmaFemaleGermanyHumansMaleMiddle AgedOutpatientsSerumSodium FluorideBlood GlucoseSodium Fluoride

Identifiers

PMID41805779
PMCPMC12974794

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked