ArticleInvestigative ophthalmology & visual science2026
In Vivo Biomechanical Characteristics of Human Corneas With Phase-Decorrelation OCT.
Article in Investigative ophthalmology & visual science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Purpose: The mechanical properties of the cornea contribute to the cornea's morphological response to surgery as well as the pathogenesis of ectatic disease states and the effects of corresponding treatment. Phase-decorrelation optical coherence tomography (PhD-OCT) is a technique which uses information acquired using a standard OCT system and, similar to dynamic light scattering techniques, calculates the temporal autocorrelation of the light backscattered from the cornea. This work seeks to assess PhD-OCT measurement repeatability and key markers in a normal clinical population. Methods: This study recruited patients who presented for refractive surgery evaluation at the Cleveland Clinic Cole Eye Institute and were deemed to be candidates for laser vision correction. In addition to standard of care assessments, PhD-OCT imaging was performed on each eye of these participants in triplicate using a commercially available anterior segment OCT scanner. Interclass correlation was calculated for repeated measurements and the PhD-OCT measurements from these normal corneas were analyzed by corneal depth and regressed against clinically relevant variables. Results: PhD-OCT consistently exhibited an anterior to posterior gradient in the measured mobility property with lower mobility/stiffer properties in the anterior stroma. PhD-OCT measurements also demonstrated very good repeatability (with an interclass correlation of 89%). Corneal thickness was not a significant contributing factor to the PhD-OCT measurements in normal eyes. PhD-OCT measurements varied significantly between some groups defined by age or sex, suggesting that there may be microstructural differences between these groups. Conclusions: PhD-OCT is a repeatable and unique measurement that can provide spatially resolved insight into a patient's corneal microstructure mobility. This approach can be implemented on existing clinical hardware.