Evidence map›Paper›PMID 41802327›Full record

ArticleUltrasonography (Seoul, Korea)2026

Low-mechanical-index B-mode phase-inversion harmonic imaging significantly improves hepatic lesion conspicuity during Sonazoid Kupffer phase: a prospective comparative study.

Jeongin Yoo, Jeong Min Lee, Hyo-Jin Kang, Jae Seok Bae

Abstract read
In one paragraph

Article in Ultrasonography (Seoul, Korea), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jeongin YooDepartment of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Jeong Min LeeDepartment of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Hyo-Jin KangDepartment of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Jae Seok BaeDepartment of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.

Funding

Canon Medical Systems Korea 06-2023-0570
6 · The paper itself

Abstract

purposeThis study compared the imaging performance of low-mechanical-index phase-inversion harmonic imaging (low-MI PIHI) with conventional contrast-enhanced ultrasonography (CEUS) during the Kupffer phase (KP) of Sonazoid-enhanced imaging for visualizing hepatic lesions, focusing on lesion conspicuity and overall image quality.

methodsThis prospective study was approved by the Institutional Review Board and included 71 patients with 72 focal liver lesions examined between February 2023 and January 2024. All patients underwent Sonazoid-enhanced CEUS. Three image sets were acquired for each lesion: baseline B-mode imaging, conventional KP imaging, and low-MI PIHI KP imaging. Two independent radiologists, blinded to clinical information, independently evaluated lesion conspicuity, border delineation, and overall image quality using a 5-point Likert scale.

resultsBaseline B-mode imaging demonstrated the lowest lesion conspicuity scores, which improved with conventional KP imaging and were highest with low-MI PIHI KP imaging (all P<0.001). Compared with conventional KP imaging, low-MI PIHI KP imaging provided significantly higher lesion conspicuity for both reviewers (P<0.001), with the most pronounced improvement observed in hepatocellular carcinomas within cirrhotic livers, where conspicuity scores nearly doubled (P<0.001). Lesion border delineation also improved significantly for both reviewers (P<0.001). Overall image quality was consistently superior with low-MI PIHI KP imaging (P≤0.003). These advantages were particularly evident for small lesions (≤2 cm) and in cirrhotic liver backgrounds.

conclusionLow-MI PIHI KP imaging significantly enhances hepatic lesion conspicuity and margin delineation compared with conventional CEUS harmonic imaging, while also improving overall image quality. These improvements may support more confident lesion detection and facilitate image-guided procedures.

Indexed as

Contrast-enhanced ultrasonographyDetectionHepatic tumorsKupffer phasePerfluorobutaneTechnique

Identifiers

PMID41802327
PMCPMC12971161

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.