HUMaN: Handheld Ultrasound System with Magnetic Needle Navigation.

Sangbum Kye, Minsung Cho, Min Kim, Manuel Berrocal, Jaime Vera, Tai-Kyong Song, Sua Bae

Abstract read
In one paragraph

Article in Ultrasonography (Seoul, Korea), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sangbum KyeDepartment of Electronic Engineering, Sogang University, Seoul, Korea.
Minsung ChoDepartment of Electronic Engineering, Sogang University, Seoul, Korea.
Min KimHansono, Seoul, Korea.
Manuel BerrocaleZono AG, Jena, Germany.
Jaime VeraeZono AG, Jena, Germany.
Tai-Kyong SongDepartment of Electronic Engineering, Sogang University, Seoul, Korea.
Sua BaeDepartment of Electronic Engineering, Sogang University, Seoul, Korea.

Funding

Ministry of Food and Drug SafetyMinistry of Health and WelfareMinistry of Science and ICT RS-2020-KD000009Ministry of Trade, Industry and EnergyNational Research Foundation of Korea RS-2025-00556887
6 · The paper itself

Abstract

purposeNeedle tip localization during ultrasound-guided procedures is challenging when the needle is poorly visualized. This study aimed to develop and evaluate a handheld ultrasound system with magnetic needle navigation (HUMaN) that integrates ultrasound imaging and real-time three-dimensional magnetic tracking within a compact form factor.

methodsHUMaN was designed using a dual-board architecture that incorporates an ultrasound probe, a real-time imaging system, and a magnetic needle guidance module that detects magnetic field disturbances to estimate needle position and orientation. The tracked needle trajectory is superimposed onto ultrasound images, and an active cooling mechanism with optimized airflow was implemented to maintain thermal stability. In vivo imaging feasibility was assessed under institutional review board approval. Needle localization accuracy was evaluated using a custom jig at multiple depths, and surface temperatures were continuously monitored during extended operation.

resultsThe system achieved sub-millimeter needle localization accuracy, with a mean bias within 0.1 mm and a precision within 0.3 mm at both 10-mm and 20-mm depths. In vivo ultrasound imaging was successfully demonstrated. Thermal evaluations showed that the device surface temperature remained well below the IEC 60601-1 safety limit (39°C) during 80 minutes of continuous operation.

conclusionHUMaN provides accurate needle localization together with fully integrated ultrasound imaging in a handheld, bracket-free design. These findings suggest that the system is well-suited for point-of-care ultrasound procedures that require portability and ease of use.

Indexed as

3D needle localizationHandheld ultrasound deviceMagnetic needle trackingNeedle guidance systemPoint-of-care ultrasoundPortable medical deviceUltrasound-guided intervention