Evidence map›Paper›PMID 41802226›Full record

ArticleJMIR human factors2026

A Summative Usability Evaluation of an Infusion Pump Through Simulation-Based Testing With Nurses: Mixed Approach Study.

Yingjun Wan, Yun Zhang, Yunlong Zhao, Han Yu, Kaifeng Liu

Abstract read
In one paragraph

Article in JMIR human factors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yingjun WanAcademy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China.ORCID 0009-0002-0641-790X
Yun ZhangTianjin Key Laboratory of Quality Control and Evaluation Technology for Medical Devices, Tianjin, China.ORCID 0009-0003-2863-7046
Yunlong ZhaoTianjin Key Laboratory of Quality Control and Evaluation Technology for Medical Devices, Tianjin, China.ORCID 0009-0000-9391-9056
Han YuAcademy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China.ORCID 0000-0002-3307-4810
Kaifeng LiuAcademy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China.ORCID 0000-0002-3993-1983

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSuboptimal design of infusion pumps may lead to usage errors, thereby compromising patient safety. Usability evaluation enables medical device design teams to identify and rectify design-related usability issues in a timely manner. Nevertheless, existing research on infusion pump usability continues to exhibit limitations in aspects such as task design.

objectiveThe study aimed to evaluate the usability of an infusion pump (SLGO SP-200 [SLGO Medical Technology Co, Ltd]) through simulation-based testing with nurses in a usability laboratory designed to simulate an intensive care unit.

methodsA total of 12 registered nurses with experience in using infusion pumps participated in this study. Nurses were asked to perform 12 operational tasks using the infusion pump. The participants were also asked to perform 7 knowledge tasks, where they were required to find relevant information in the user manual. Participants' behavioral measures (task completion time, frequency of manual query, frequency of asking for assistance from researchers, frequencies of operation difficulties, near-misses, and failures), perceptions (perceived ease of use, perceived concentration level required, perceived likelihood of making programming errors, perceived mental workload, satisfaction, and use intention) were collected to evaluate the usability and identify interface design deficiencies of the pump.

resultsThe study found that the participants were generally able to complete the tasks. All operational tasks were completed within 3 minutes, and all knowledge tasks were completed within 2 minutes. Our study identified 79 difficult operations, 9 near-miss operations, and 36 operation failures. The causes of the above problems were analyzed. Participants generally found the infusion pump to be user-friendly, requiring a medium level of attention resources, and reported low levels of mental workload and likelihood of making programming errors.

conclusionsThe study results can provide a basis for the design of infusion pumps, help practitioners define the risks of use and the key content of training, and provide an important reference for the design of usability evaluation schemes for medical devices.

Indexed as

Equipment DesignInfusion PumpsNursesAdultFemaleHumansinfusion pumpmedical devicesimulated useusabilityuse error

Identifiers

PMID41802226
PMCPMC13010072

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.