Evidence map›Paper›PMID 41801301›Full record

Trial reportArchives of orthopaedic and trauma surgery2026

Properly designed femoral stem impactors help to avoid overstuffing and make a second trial reduction unnecessary.

Steffen Brodt, Sebastian Rohe, Philipp Knospe, Pablo Sanz-Ruiz, Georgi Wassilew, Georg Matziolis

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Steffen BrodtOrthopaedic Department, Jena University Hospital, Campus Eisenberg Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany. s.brodt@waldkliniken-eisenberg.de.ORCID http://orcid.org/0000-0003-1286-8766
Sebastian RoheOrthopaedic Department, Jena University Hospital, Campus Eisenberg Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Philipp KnospeOrthopaedic Department, Jena University Hospital, Campus Eisenberg Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Pablo Sanz-RuizDepartment of Orthopaedic Surgery, General University Hospital Gregorio Marañón, Madrid, Spain.
Georgi WassilewCenter for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Greifswald, Germany.
Georg MatziolisOrthopaedic Department, Jena University Hospital, Campus Eisenberg Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFor cementless implantation of hip stems, it is very important that the original stem fits exactly into the femoral prosthesis bed previously shaped using a stem rasp. If the geometry of the stem rasp does not match the prosthesis geometry, this can result in either overstuffing or post-sintering of the original stem in relation to trial reduction with the stem rasp. Overstuffing results in leg lengthening, while subsidence of the stem results in shortening with the risk of dislocation and impingement. Trial reduction with the original stem and trial head can prevent this, but is associated with additional soft tissue trauma and a longer operating time. MATERIALS AND

methodsThree groups were prospectively randomized. Group 0 was treated with the Fitmore B stem and the conventional rasp system, Group 1 with the Optimys stem and Group 2 with the Fitmore B stem with a new, optimized rasp system via a minimally invasive posterolateral approach. Intraoperatively, the differences in leg length and offset between trial reduction with the stem rasp and the original stem were recorded using a hip navigation system.

resultsThe conventional rasp system led to significant overstuffing (1.2 ± 0.5 mm, p = 0.024) with the Fitmore B stem, compared with the instruments of the Optimys stem. In contrast, the optimized rasp system with the Fitmore B stem resulted in an equally precise fit of the endoprosthesis to that achieved with Optimys.

conclusionThere are relevant differences in the fit of rasp and original stem between different manufacturers and system evolutions. In order to ensure reproducible comparability of the fit of the original stem to the trial rasp, it is imperative that trial rasps are optimally adapted to the stems. This is an important way to avoid trial reduction after implantation of the original stem.

trial registrationThis study was registered in the German Clinical Trials Register (Deutsches Register Klinischer Studien) with the registration number DRKS00026749.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisProsthesis DesignFemaleHumansMaleProspective StudiesHip stemNavigationOverstuffingSubsidenceTHATotal hip arthroplasty

Identifiers

PMID41801301
PMCPMC12971795

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.