ArticlePlastic and reconstructive surgery. Global open2025
Prevention of Pressure-induced Soft Tissue Injuries in Acute and Chronic Hospital Settings: A Biomechanical Comparison of Current Methods and Materials.
Article in Plastic and reconstructive surgery. Global open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Hospital-acquired pressure injuries are common for immobilized, intubated, and anesthetized patients. Current padding products fail to alleviate excessive pressure, leading to patient harm and significant healthcare burden. This study compared current pressure-avoiding materials used in the clinical setting with a novel silicone-based pressure relief system. Methods: Seven "in clinical use" padding materials were systematically tested across 4 conditions: new, after 2 hours of 100 lbs load bearing, saturated (after 12 hours soaked in saline), and saturated after load bearing. Each test condition was performed on 4 unique samples totaling 76 tests. Electron microscopy was performed to determine material integrity. Results: Polyurethane foams demonstrated similar mechanical properties throughout testing. The eggcrate foam showed almost complete collapse under all conditions. All polyurethane foams demonstrated 13.2% ± 20.8 less force required to cause deformation when saturated ( Conclusions: Currently, a static, one-size-fits-all product approach is insufficient in addressing the pressure injury global issue. We present biomechanical data on a novel customizable open-cell silicone foam as a potential new surface padding solution, demonstrating equivalency and improved structural characteristics over time compared with current padding materials.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.