Evidence map›Paper›PMID 41797854›Full record

ArticleJournal of arrhythmia2026

Anatomical Predictors of Optimal Cryoballoon Size Selection: A Prospective Comparison of 28 mm Versus 31 mm Size-Adjustable Balloon Modes.

Reisuke Yoshizawa, Takeshi Sasaki, Harutomo Numazaki, Keisuke Kaminaga, Kotaro Mori, Satoru Taguchi, Hiroki Sasaki, Takashi Urushikubo, Kyohei Nagata, Yohei Sawa and 3 more

Abstract read
In one paragraph

Article in Journal of arrhythmia, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Reisuke YoshizawaDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.ORCID https://orcid.org/0000-0001-8790-9169
Takeshi SasakiDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Harutomo NumazakiDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Keisuke KaminagaDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Kotaro MoriDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Satoru TaguchiDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Hiroki SasakiDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Takashi UrushikuboDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Kyohei NagataDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Yohei SawaDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Shingen OwadaDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.
Fumiaki TakahashiDivision of Medical Engineering, Department of Information Science Iwate Medical University School of Medicine Yahaba Japan.
Yoshihiro MorinoDivision of Cardiology, Department of Internal Medicine Iwate Medical University School of Medicine Yahaba Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Complete pulmonary vein (PV) occlusion is critical for successful cryoballoon ablation. The POLARx FIT size-adjustable cryoballoon adjusts diameter from 28 to 31 mm. This study aimed to compare PV occlusion grades between balloon modes and identify anatomical predictors for optimal size selection. Methods: This prospective study included 150 consecutive patients undergoing cryoballoon ablation for atrial fibrillation. PV occlusion was assessed using contrast injection (Grades I-IV) for both balloon sizes before ablation. Pre-procedural computed tomography measurements included PV dimensions, ovality index, trunk length, and PV angles in frontal and transversal planes. Generalized Estimating Equations analysis accounted for within-patient correlation. Results: Complete occlusion in all four PVs was achieved in 106/150 patients (70.7%) with 31 mm versus 85/150 (56.7%) with 28 mm mode ( Conclusion: The 31 mm mode significantly improves occlusion rates, particularly in superior PVs, while 28 mm is adequate for inferior PVs. Larger PV diameter and higher ovality index predict incomplete occlusion, supporting preferential use of 31 mm mode for larger, more oval PVs. Validation in multicenter cohorts is required.

Indexed as

atrial fibrillationcryoballoon ablationpulmonary vein anatomypulmonary vein isolationpulmonary vein occlusion

Identifiers

PMID41797854
PMCPMC12966354

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.