A comparative study between two commonly used robotic systems on the accuracy of the intraoperative cuts in total knee arthroplasty.

S S Liong, W C Lee, S K M Khoo, B R K Chee, R Kunnasegaran

Abstract read
PubMed Publisher
In one paragraph

Article in Musculoskeletal surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

S S LiongDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore. liongsoosian@gmail.com.ORCID http://orcid.org/0009-0002-9139-3198
W C LeeDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore.
S K M KhooDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore.
B R K CheeDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore.
R KunnasegaranDepartment of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe aimed to compare the accuracy of robotic Total Knee Arthroplasty (TKA) intraoperative cuts between Computed Tomography image-based MAKO and imageless ROSA.

methodsWe retrospectively analysed registry data for patients who underwent imaged-based MAKO and imageless ROSA robotic TKA. Two reviewers independently radiographically measured the coronal alignment of the implants in relation to the mechanical axis at 3 months post-operation. These were compared to the planned intraoperative robotic cuts.

resultsOne hundred sixty-one patients underwent MAKO and 110 ROSA TKA. Intraclass correlation for radiographic readings was 0.88 to 0.96. When comparing the variability between intraoperative planned alignment and 3 months postoperative, MAKO femur showed no statistically significant difference (- 0.1° ± 0.8° vs. - 0.1° ± 1.2°, p = 0.12) and likewise no difference for tibia (- 0.9° ± 1.2° vs. - 0.6° ± 1.3°, p = 0.60). However, for ROSA, its femur showed statistically significant difference (- 1.2° ± 1.0° vs. - 0.7° ± 1.3°, p < 0.01), likewise for tibia (- 0.4° ± 0.9° vs. - 0.2° ± 1.4°, p < 0.01). The variability from intraoperation to 3 months postoperative was significantly different between MAKO and ROSA for femur (0.0° ± 1.0° vs. 0.4° ± 1.1°, p < 0.01), but was not statistically significant for tibia (0.3° ± 0.1° and 0.1° ± 1.1°, p = 0.26). There was a significant difference with a larger proportion of femur implant that deviated < 1º from intraoperative plan in MAKO compared to ROSA (62.1% and 37.2% respectively, p < 0.01). At the tibia component, there was no statistically significant difference in the proportion of the extent of deviation (p = 0.73).

conclusionThere was statistically significant variability in coronal alignment between intraoperative plan and postoperative 3 months in the imageless robotic system at both femur and tibia components. The extent of variability between the imageless and CT-image based systems in femur was also statistically significant. There was also a larger proportion of implant deviation of > 1º in the femur component in imageless robotic system. Nevertheless, the overall extent of the deviation between the intraoperative plan and the postoperative position was < 0.5º. Future studies may be performed to determine whether this would translate into any clinical significance.