Evidence map›Paper›PMID 41796213›Full record

ArticleChild's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery2026

Avoiding overdrainage with M.blue valve in pediatric hydrocephalus: efficiency, complications and valve survival.

M Estela Plaza-Ramírez, Pablo Miranda-Lloret, Giovanni Pancucci, Alejandro Zurita-Saa, Adrian Verdú-Ferrer, J Antonio Simal-Julián

Abstract read
PubMed Publisher
In one paragraph

Article in Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

M Estela Plaza-RamírezDepartment of Neurosurgery, La Fe University and Polytechnic Hospital, Valencia, Spain. plaza_marram@gva.es.ORCID 0000-0002-6923-6834
Pablo Miranda-LloretDepartment of Neurosurgery, La Fe University and Polytechnic Hospital, Valencia, Spain.ORCID 0000-0003-3623-5744
Giovanni PancucciDepartment of Neurosurgery, La Fe University and Polytechnic Hospital, Valencia, Spain.
Alejandro Zurita-SaaDepartment of Neurosurgery, La Fe University and Polytechnic Hospital, Valencia, Spain.ORCID 0009-0000-3739-5892
Adrian Verdú-FerrerDepartment of Neurosurgery, La Fe University and Polytechnic Hospital, Valencia, Spain.
J Antonio Simal-JuliánDepartment of Neurosurgery, La Fe University and Polytechnic Hospital, Valencia, Spain.ORCID 0000-0002-3829-8354

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeOverdrainage (OD) is a significant long-term complication in shunted pediatric patients and remains difficult to prevent consistently. The M.blue valve is an adjustable gravity-assisted (GA) device designed to address this issue. This study aims to add experience about the use of M.blue in pediatric hydrocephalus.

methodsA retrospective review was conducted on children under 15 years who received M.blue valves between April 2019 and October 2023 at La Fe University and Polytechnic Hospital. Data collected included demographics, hydrocephalus etiology, indications for M.blue implantation, changes of pressure settings over time, valve efficacy in OD control, associated complications, and valve survival.

resultsA total of 100 M.blue valves were implanted in 77 children (mean age: 5.77 ± 4.7 years; 44 males, 33 females). Mean follow-up was 36.92 months (range: 12-66). The most frequent etiology of hydrocephalus was posthemorrhagic hydrocephalus in preterm infants (29.9%), followed by tumor-related hydrocephalus (10.4%). M.blue was used for prevention in 32 cases (41.5%) and for treatment in 45 (58.5%). There were 197 pressure readjustments, with an overall trend toward increasing pressure settings over time; six cases required a setting of 40 cmH₂O. OD was prevented in 81.2% and successfully treated in 84.4% of cases. Complications included blockage of the adjustability mechanism in 38 of 78 tested valves (48.7%), with clinical impact in 20 cases (25.6%) and requiring surgical replacement in 12 (15.4%). Age under 2 years was the only factor associated with blockage (p < 0.005). Spontaneous pressure changes occurred in nine valves, six of which were simultaneously linked to adjustability failure, four of them requiring surgical replacement. Seven additional cases showed valvular obstruction with clinical deterioration. Only three cases developed ventricular catheter obstruction. Shunt survival rates at 1 and 3 years were 82% and 62%, respectively. Younger age at implantation was associated with higher rates of blockages of the adjustability mechanism and revisions.

conclusionsThe M.blue valve is effective in preventing and treating OD in children, with good shunt survival and low incidence of catheter obstruction. Progressive pressure increases are often required to control OD, reflecting dynamic CSF physiology and the unpredictability of optimal settings. The main limitation is the frequent blockage of the adjustability mechanism, followed by spontaneous pressure changes and valve obstruction.

Indexed as

HydrocephalusPostoperative ComplicationsVentriculoperitoneal ShuntAdolescentChildChild, PreschoolFemaleHumansInfantMaleRetrospective StudiesTreatment OutcomeM.blue valveOverdrainageProgrammable gravity valveShunted pediatric hydrocephalus

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.