ArticleJournal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine2026
A Novel Slit Lamp-Based System for 3D Ultrasound of the Eye.
Article in Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
objectivesThis study aims to develop and evaluate a novel slit-lamp-based system to acquire 3-dimensional (3D) ultrasound volumes using conventional ultrasound probes.
methodsA slit-lamp adapter was 3D printed and connected with a linear actuator and graphical user interface (GUI) system to control movement and create volumes of 2-dimensional scans. The ultrasound probe contacted the patient's cornea to perform the scan. The GUI software was designed to acquire and process b-scan images, which were exported to 3D Slicer and manually annotated. The annotated images were used to render 3D renderings of ophthalmic anatomy using MATLAB and 3D Slicer.
resultsThe optimal resolution, quality, scan type, and patient comfort were determined through simulations. Higher scan numbers and light contact pressure resulted in sufficient image clarity. Out of 250 completed scans, four 3D ultrasound models were created, depicting diagnoses such as tractional retinal detachment, choroidal hemorrhage, and myopia. These models were compared with traditional imaging methods.
conclusionsThe study successfully created 3D ultrasound scans using a novel slit-lamp-based system and manual annotation. The accuracy of the models was comparable to other imaging forms and demonstrated greater details. This study represents a significant step toward an accessible point-of-care ultrasound system in ophthalmology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.