Evidence map›Paper›PMID 41795603›Full record

ArticleJournal of clinical ultrasound : JCU

Ultrasonography Sliding Sign as a Predictor for Intraabdominal Adhesions in Repeated Cesarean Deliveries: Retrospective Cross Sectional Study.

Can Ata, Ufuk Atlihan, Onur Yavuz, Huseyin Aytug Avsar

Abstract read
In one paragraph

Article in Journal of clinical ultrasound : JCU. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Can AtaDepartment of Obstetrics and Gynecology, Izmir Demokrasi University, Buca Seyfi Demirsoy Training and Research Hospital, Izmir, Turkey.ORCID https://orcid.org/0000-0002-0841-0480
Ufuk AtlihanDepartment of Obstetrics and Gynecology, Merkezefendi Hospital, Manisa, Turkey.ORCID https://orcid.org/0000-0002-2109-1373
Onur YavuzDepartment of Obstetrics and Gynecology, Dokuz Eylul University School of Medicine, Izmir, Turkey.ORCID https://orcid.org/0000-0003-3716-2145
Huseyin Aytug AvsarDepartment of Obstetrics and Gynecology, Tinaztepe University School of Medicine Galen Hospital, Izmir, Turkey.ORCID https://orcid.org/0000-0003-0636-3104

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOur objective was to evaluate the ultrasonography sliding sign with enhanced reliability using an inter-observer approach, with the aim of predicting standardized intra-abdominal adhesions before cesarean section.

methodsBetween January 2022 and January 2024, this retrospective cross sectional study included 350 individuals who underwent cesarean section. Data from 198 participants who met the inclusion criteria were analyzed. Analyzes were made with SPSS 26.0. The Mann-Whitney U test was employed to assess variables that were not normally distributed. Chi-square test and Fisher precision test were employed in the categorical data analysis. These were presented as counts and percentages (%). An inter-rater reliability analysis was performed for ultrasonography sliding sign finding. For this purpose, the Cohen's Kappa was calculated. Receiver operating characteristic analysis was used to determine the area under the curve, which indicates the average sensitivity of ultrasonography sliding sign finding. There was a 95% confidence interval for the results. A p value of less than 0.05 was deemed statistically significant. To assess sliding signs, all pregnant participants received transabdominal ultrasonography. The study achieved triple masking: both sonographers were unaware of the surgical findings, the surgeon remained unaware of the ultrasound findings, and the data analyst was unaware of both sonographic and surgical findings. According to the Nair's modified scoring system, the cases were classified as Group 1 (adhesions present [Grade ≥ 1]; n = 107, 54%) and Group 2 (no adhesions [Grade 0]; n = 91, 46%).

resultsThe diagnostic value of transabdominal ultrasonography sliding sign for detecting the presence of intra-abdominal adhesion (according to the modified Nair's scoring system) yielded 84.6% specificity and 58.9% sensitivity. A Nair's score ≥ 2 was identified as the cut-off point, with the sliding sign finding being statistically significant, resulting in 70% specificity and 54% sensitivity.

conclusionThis research validates the use of a sliding sign during transabdominal ultrasonography in pre-cesarean evaluation in patients with previous cesarean section. It has been shown that applying the adhesion scoring system categorically as well as using it numerically makes a difference by analyzing the cut-off point of Nair's score as 2. From this perspective, the reliability of the sliding sign finding in transabdominal ultrasound will be better demonstrated.

Indexed as

Cesarean SectionCesarean Section, RepeatPostoperative ComplicationsAbdomenAdultCross-Sectional StudiesFemaleHumansPredictive Value of TestsPregnancyReproducibility of ResultsRetrospective StudiesSensitivity and SpecificityTissue AdhesionsUltrasonographycesarean sectionmodified Nair's scoring systemNair's scoring systemsliding signultrasonography

Identifiers

PMID41795603
PMCPMC13332566

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.