ArticleVeterinary clinical pathology2026
Comparison of the Calibrated Automated Thrombogram Using Standard and Low Plasma Volumes in Dogs.
Article in Veterinary clinical pathology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundThrombin generation assessment using calibrated automated thrombography (CAT) requires a standard volume of plasma (80 μL) and reagent (20 μL) run in triplicate. A CAT method using lower plasma and reagent volumes could benefit veterinary patients as it lowers the sampling burden in patients.
objectivesTo compare standard CAT methodology to a low plasma and low reagent volume CAT method in dogs.
methodsPlatelet-poor plasma samples were obtained by direct jugular venipuncture in dogs with low (n = 10), high (n = 10), and normal (n = 10) thrombin generation potential, recruited from a tertiary referral hospital. Method comparison was performed between standard CAT (80 μL plasma, 20 μL reagent- method 1) and low volume CAT (40 μL plasma, 10 μL reagent- method 2). Lag time (lag time); endogenous thrombin potential (ETP); peak (peak); and time to peak (ttpeak) were assessed on the thrombin generation curves.
resultsThere was excellent agreement between methods 1 and 2 for all parameters. Lin's concordance coefficients were 0.97, 0.94, 0.96, and 0.96 for lag time, ETP, ttpeak, and peak, respectively. There was a small bias for all parameters (p < 0.05), resulting in a significant change for lag time only. There was a significant predictive linear equation that, when modeled, allowed the conversion of method 2 to method 1 values. The methods had similar variation when measuring TG variables.
conclusionsBased on the results in this small group of dogs, we conclude that low-volume CAT appears to be an alternative to the standard testing method in dogs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.