ArticleCommunications engineering2026
A wireless power transfer system for leadless endovascular electrocorticography.
Article in Communications engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Endovascular approaches to neural interfacing: lessons from cardiovascular technologies.Frontiers in neuroscience · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Wireless power transfer (WPT) for stent-based neuroprosthetic devices, such as endovascular electrocorticography (endoECoG) systems, is typically constrained by the need for long lead wires to subcutaneous chest implants. This study presents a method for delivering power directly to an unmodified medical stent. The proposed system employs a subcutaneous relay that converts inductive coupling to capacitive coupling, thereby improving power transfer efficiency, reducing invasiveness, and mitigating instability in skin-contact capacitance. Experimental validation using skin, bone, and vessel tissues, combined with finite element simulations, demonstrated over 45 mW of delivered power, sufficient for endoECoG and biosignal sensing. The proposed system achieved 7.26% DC-to-DC efficiency, the highest reported for stent-based implants without custom stents or auxiliary transceivers. Measured results closely matched simulations, validating the experiment results. Safety assessments, including specific absorption rate and thermal analysis, confirmed compliance with regulatory limits. While the experimental results indicate robust performance, further theoretical analysis is required to establish a complete mechanistic understanding of the underlying coupling processes. The proposed architecture enables efficient, safe, and fully wireless power delivery to endovascular implants without requiring close skin contact, supporting long-term implantation, enhancing patient comfort, and facilitating future clinical translation.