Evidence map›Paper›PMID 41792197›Full record

ArticleScientific reports2026

Evaluation of S-Value in relation to cochlear anatomy in pediatric cochlear implant users.

Marzouqi A Salamah, Yassin Abdelsamad, Bader Alwhaibi, Abdullah Alzamil, Abdulrahman Alsanosi

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Marzouqi A SalamahDivision of Otorhinolaryngology-Head and Neck Surgery, Department of Surgery, King Abdulaziz Medical City, P.O. Box 22490, 11426, Riyadh, Saudi Arabia. marzouqi.salamah@gmail.com.ORCID http://orcid.org/0000-0003-2018-0056
Yassin AbdelsamadDepartment of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium. Yassin.samad@medel.com.ORCID http://orcid.org/0000-0001-8281-5825
Bader AlwhaibiCollege of Medicine, King Saud University, Riyadh, Saudi Arabia.
Abdullah AlzamilCollege of Medicine, King Saud University, Riyadh, Saudi Arabia.
Abdulrahman AlsanosiKing Abdullah Ear Specialist Center (KAESC), King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To assess the S-value in pediatric cochlear implant (CI) patients using high-resolution CT images and examine its correlation with main cochlear parameters and angular insertion depth (AID). A retrospective review of preoperative CT images from pediatric CI recipients with normal cochlear anatomy was conducted at a referral hearing implant center. Cases involving congenital or acquired inner-ear abnormalities were excluded. Two independent reviewers with equivalent expertise used OTOPLAN to measure the main cochlear parameters, and the interrater reliability study revealed good agreement. S-values (the straight section of the cochlear basal turn) were measured and examined, and their correlation to electrode insertion angles and cochlear parameters (A- and B-values) was evaluated. The average cochlear duct length (CDL) of the included patients was 36.14 ± 0.26 mm, with an average S-value of 7.06 ± 0.40 mm, insertion angle of 598.20° ± 48.72°, and cochlear coverage of 77.49% ± 0.57. A statistically significant relationship was found between A- and the S-values (r = 0.65, p = 0.004). However, the B-value showed a moderate, non-significant correlation with the S-value (r = 0.43). Furthermore, a consistent negative, but not statistically significant, association was found between the S-value and the angular insertion depths of all electrode contacts (r = - 0.28 to - 0.30). The S-value is a dependable anatomical parameter that correlates positively with the A-value. The evaluated lateral-wall array showed consistent insertion depths among patients with similar CDL, even when S-values differed. Further studies are needed to investigate the impact of greater variability in S-values on clinical outcomes and electrode-array position among CI users.

Indexed as

CochleaCochlear ImplantationCochlear ImplantsChildChild, PreschoolCochlear DuctFemaleHumansInfantMaleRetrospective StudiesTomography, X-Ray ComputedCochlear implantCochlear lengthCochlear metricsInsertion angleOTOPLAN

Identifiers

PMID41792197
PMCPMC12979654

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.