ArticleFrontiers in pediatrics2026
Objective interpretation of intrapartum cardiotocography images using attention-guided convolutional neural networks.
Article in Frontiers in pediatrics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: Automated analysis of Electronic Fetal Monitoring (EFM) is essential for the precise assessment of fetal health. However, the subjective interpretation and expertise-dependent nature of conventional cardiotocogram (CTG) analysis hinder diagnostic consistency. This study aims to develop an objective interpretation approach comprising a systematic preprocessing pipeline for signal reconstruction and an attention-guided convolutional neural network for pattern classification to mitigate the risk of missed diagnoses. Methods: A computer vision-based deep learning approach was developed. The workflow begins with a systematic preprocessing pipeline, where raw CTG images undergo grid removal, resampling, and curve reconstruction to generate standardized signal inputs. These signals are analyzed by a classifier based on the EfficientNet-B0 architecture, enhanced with a Convolutional Block Attention Module (CBAM). This attention mechanism enables the model to focus on clinically significant morphological features. The model was trained on a private clinical dataset using clinician-labeled FIGO classifications (Normal vs. Suspicious/Abnormal) as the primary outcome. To evaluate its clinical utility and robustness, the model was externally validated on the public CTU-UHB dataset, using objective umbilical artery pH levels (pH Results: On the internal clinical dataset, the model achieved an accuracy of 92.66% and a macro-average F1-score of 92.14%. When tested on the external CTU-UHB dataset, the model maintained an accuracy of 95.65%. These results indicate that the proposed algorithm aligns with expert visual classification and remains consistent when validated against objective physiological outcomes (pH levels). This consistency across benchmarks supports the potential robustness and clinical relevance of the learned morphological features. Conclusion: This study presents an objective method for intrapartum CTG analysis. By integrating signal standardization with automated feature learning, the proposed approach addresses the inherent subjectivity of manual interpretation. It serves as a potential clinical decision support tool to assist in the consistency of fetal status assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.