ArticleJournal of cardiology cases2026
Retrieval of a dislodged helix-fixation leadless pacemaker using the double-snare technique: A case report.
Article in Journal of cardiology cases, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Leadless pacemakers (LPs) reduce the risk of lead-related complications, but early dislodgement remains a rare yet serious adverse event. We report the case of an 88-year-old woman with bradycardia-tachycardia syndrome who underwent implantation of an AVEIR™ VR LP (Abbott, Chicago, IL, USA). The procedure was uneventful, with stable electrical parameters and confirmed fixation. However, pacing failure was detected the following day, and imaging revealed that the device had dislodged into the right pulmonary artery. Given the position and orientation of the dislodged device, the dedicated retrieval catheter was deemed unsuitable. Therefore, the double-snare technique was employed using two snare catheters: one inserted through a steerable sheath to grasp the device body, and the other advanced outside the sheath to secure the helix. This approach enabled safe and complete retrieval without vascular injury. The patient subsequently underwent successful transvenous dual-chamber pacemaker implantation and was discharged without complications. Notably, a small amount of myocardial tissue was found attached to the helix, suggesting possible localized myocardial fragility. This case highlights the utility of the double-snare technique as an effective alternative when standard retrieval tools are inadequate for recovering dislodged LPs. Learning objective: Leadless pacemaker (LP) dislodgement into the pulmonary artery is a rare but serious complication that requires prompt recognition and appropriate retrieval. The double-snare technique provides a safe and effective option when standard methods are insufficient. Awareness of potential underlying factors, such as localized myocardial fragility, may guide risk assessment and management. Understanding such cases enhances patient safety and supports best practices in LP therapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.