Evidence map›Paper›PMID 41788617›Full record

ArticleClinical kidney journal2026

Intradialytic hypotension is severely underreported by intermittent blood pressure readings.

Sabrine Chaara, Muriel P C Grooteman, Menso J Nubé, Willem Jan W Bos, Paul A Rootjes, Gertrude Wijngaarden, Camiel L M de Roij van Zuijdewijn

Abstract read
In one paragraph

Article in Clinical kidney journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sabrine ChaaraDepartment of Internal Medicine, division of Nephrology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
Muriel P C GrootemanDepartment of Internal Medicine, division of Nephrology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
Menso J NubéDepartment of Internal Medicine, division of Nephrology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
Willem Jan W BosDepartment of Internal Medicine, St. Antonius Hospital, Nieuwegein, the Netherlands.
Paul A RootjesDepartment of Internal Medicine, division of Nephrology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
Gertrude WijngaardenDepartment of Internal Medicine, division of Nephrology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
Camiel L M de Roij van ZuijdewijnDepartment of Internal Medicine, division of Nephrology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.ORCID https://orcid.org/0000-0002-6369-8341

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Intradialytic hypotension (IDH) has been associated with both morbidity and mortality. Yet, as IDH often occurs asymptomatic, it might be easily missed with routine twice per hour brachial artery cuff-blood pressure (BAC-BP) readings. This study evaluated differences in IDH detection between intermittent BAC-BP and continuous BP monitoring with a finger cuff (FC-BP). Validation of the FC device was an additional objective. Methods: In 40 chronic dialysis patients, intradialytic BP was measured during four sessions using (i) BAC-BP every 15 minutes and (ii) beat-to-beat FC-BP readings, which were averaged over 20-seconds intervals. IDH was defined as a systolic BP (SBP) <90 or <100 mmHg, depending on pre-dialysis SBP. Only FC measurements with an acceptable accuracy (i.e. mean SBP bias ≤10 mmHg) were used for the IDH analysis. For validation, sequential same-arm BP measurements were compared, using Bland-Altman analyses to assess agreement and four-quadrant plots to evaluate concordance. Results: For IDH analysis, 144 BAC-BP readings and 18 163 FC-BP measurements were recorded in 106 hours. While BAC-BP identified 20 IDH episodes, 441 were detected by FC-BP. For validation, Bland-Altman analyses of 1221 paired BP readings showed a mean bias ± limits of agreement of -13.3 ± 44.5 mmHg for SBP and -13.3 ± 25.5 mmHg for diastolic BP. Only 27.7% of the paired FC-BP readings met the acceptable accuracy criterion. Concordance rates were 34.3% and 36.3%, respectively. Conclusions: First, the occurrence of IDH is severely underestimated with intermittent BP monitoring. Second, FC-BP appears unsuitable for routine intradialytic BP monitoring due to its poor accuracy, precision, and concordance.

Indexed as

blood pressurefinger cuffhaemodiafiltrationhaemodialysisintradialytic hypotension

Identifiers

PMID41788617
PMCPMC12957917

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.