Evidence map›Paper›PMID 41787904›Full record

ArticleArchives of craniofacial surgery2026

Surgical precision and clinical outcomes of 3D preformed titanium mesh in orbital blowout fracture reconstruction: a comparative study from Thailand.

Chatchai Pruksapong, Navin Klongkitkarnkha, Akaradech Attainsee, Chairat Burusapat, Suttisun Jankajorn, Nutthapong Wanichjaroen, Nuttadon Wongprakob, Rapeepat Sapruangthong, Pantip Suwansa-Ard

Abstract read
In one paragraph

Article in Archives of craniofacial surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Chatchai PruksapongDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Navin KlongkitkarnkhaDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Akaradech AttainseeDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Chairat BurusapatDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Suttisun JankajornDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Nutthapong WanichjaroenDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Nuttadon WongprakobDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Rapeepat SapruangthongDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Pantip Suwansa-ArdDepartment of Radiology, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOrbital floor fractures are frequently associated with head trauma, and the complex three-dimensional (3D) structure of the orbital cavity poses a significant challenge for accurate repair of orbital wall defects. Accordingly, this study aimed to compare preoperative titanium mesh bending using 3D-printed models with conventional intraoperative bending techniques, focusing on the accuracy of orbital geometry reconstruction and intraoperative efficiency, with the goal of determining potential advantages in optimizing surgical outcomes.

methodsThis study presents a comparative analysis between a prospective preoperative bending (3D pre-bent) of titanium mesh and retrospective data from conventional intraoperative bending. Clinical and radiographic evaluations of orbital geometry, along with intraoperative efficiency metrics, were assessed at both preoperative and postoperative stages.

resultsSixty-four patients were included, with 32 in the 3D pre-bend titanium mesh group and 32 in the conventional bending group. Mean operative time was shorter in the 3D pre-bend group (81.07± 13.04 minutes) than in the conventional group (96.07± 4.46 minutes). The 3D pre-bend group achieved more accurate reconstruction, with orbital volume and height correction rates of 96.78% ± 4.91% and 100.62%± 3.77%, respectively, versus 94.88% ± 4.33% and 96.08% ± 5.44% in the conventional group. Patient and surgeon satisfaction was higher in the 3D pre-bend group.

conclusionPre-bending titanium mesh using a 3D-printed model significantly reduces intraoperative time and improves orbital height correction. Additionally, this technique enhances both patient and surgeon satisfaction. However, long-term clinical outcomes remain comparable between groups.

Indexed as

MeshProspective studiesTitaniumTreatment outcome

Identifiers

PMID41787904
PMCPMC12968646

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.