ArticleArchives of orthopaedic and trauma surgery2026
Outcomes of internal fixation for pediatric proximal femoral fractures using a 3.5 mm T-plate.
Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThis study aims to investigate the functional and radiographic outcomes after internal fixation of proximal femoral fractures in children using a 3.5 mm T-plate.
methodsFrom December 2015 to September 2022, all cases presenting with recent proximal femoral fractures were treated with internal fixation using a 3.5 mm T-plate. All patients were followed up for 24 months. Union time, neck shaft angle, neck length, quality of reduction, and functional outcomes were assessed.
resultsThe study included 37 patients; the mean age was 8.6+/- 1.6 (6–11) years. Delbet type IV was the most frequent fracture type (13 cases, 35.1%), followed by type V (10 cases, 27%), and type III (9 cases, 24.3%), with type II accounting for 5 cases. All fractures achieved union with a mean time of 8,7 weeks (range 6–12 weeks), As regards radiographic parameters, the mean neck shaft angle difference was 4.9 (SD 3.7) degrees (range 0–16 degrees) less than the contralateral side, the mean neck resorption ratio was 93.8 +/- 4 (range 85–100), The quality of reduction was anatomical in 24 cases (64.9%), acceptable in 10 cases (37%), and considered unacceptable in 3 cases (8.1%), The functional outcome was good in 24 cases (64.9%), fair in 11 patients (29.7%) and poor in two patients (5.4%).
conclusionThe use of a contoured 3.5 mm conventional T-plate in the fixation of recent pediatric femoral fractures (types II–V) yields good results regarding union rates, functional outcome, and maintaining the mechanics of the hip.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.