Evidence map›Paper›PMID 41783885›Full record

ArticleCureus2026

Clinical Audit of Transfusion Safety and Monitoring at Al-Kareemat Specialized Complex, Sudan: A Two-Cycle Quality Improvement Study.

Shimaa Ali Hassan Hamed, Abubaker Ibrahim Mohammed Ibrahim, Zainab Abdelrahman Mohamed Ali, Ahd A Ahmed Abdelghani, Rowida A Ahmed, Sana Taha Ibrahim Taha, Yosria Alneel Edrees Alneel, Sara Hassan Siddig Mohamed, Rana Mohamedosman Babiker Karrar, Amna Alhafiz and 2 more

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Shimaa Ali Hassan HamedInternal Medicine, University of Bahri, Khartoum, SDN.
Abubaker Ibrahim Mohammed IbrahimInternal Medicine, Department of Medicine, Delma Hospital, Abu Dhabi, ARE.
Zainab Abdelrahman Mohamed AliFaculty of Medicine, Elrazi University, Khartoum, SDN.
Ahd A Ahmed AbdelghaniInternal Medicine, Sudan Medical Specialization Board, Khartoum, SDN.
Rowida A AhmedGeneral Medicine, NMC Royal Hospital, Abu Dhabi, ARE.
Sana Taha Ibrahim TahaGeneral Practice, Meena Health Care, Riyadh, SAU.
Yosria Alneel Edrees AlneelInternal Medicine, Sharaf Hospital, Hail, SAU.
Sara Hassan Siddig MohamedInternal Medicine, Hail General Hospital, Hail, SAU.
Rana Mohamedosman Babiker KarrarFamily Medicine, Al Hada Armed Forces Hospital, Taif, SAU.
Amna AlhafizInternal Medicine, Saudi German Hospital, Madinah, SAU.
Asim AhmedMedicne and Surgery, University of Gezira, Wad Madani, SDN.
Nosiba Abd Alraheem Aljack Awad AlkareemGeneral Practice, Bassam First Medical Company, Duba, SAU.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBlood transfusion is a lifesaving intervention; however, preventable harm can occur when bedside identification, monitoring, and documentation are incomplete. We focused on these bedside steps because they are safety critical, reduce the risk of wrong patient transfusions, and support early recognition of transfusion reactions.

objectiveTo assess compliance with World Health Organization (WHO)-aligned bedside transfusion safety and monitoring criteria and hemovigilance reporting at the Al-Kareemat Specialized Complex for Clinics and Inpatient Care in Sudan, and to evaluate changes after a targeted quality improvement intervention using a two-cycle closed-loop audit design. This audit evaluated compliance with WHO-aligned transfusion safety, monitoring, and hemovigilance protocols at the Al-Kareemat Specialized Complex for Clinics and Inpatient Care in Sudan.

methodsA closed-loop, two-cycle documentation-based clinical audit was conducted. The baseline cycle retrospectively reviewed 220 transfusion episodes administered between January and June 2024 using a structured checklist assessing eight bedside safety and monitoring criteria and hemovigilance indicators; absent documentation was classified as noncompliance. Following implementation of a targeted quality improvement package, focused on staff reinforcement and standardized monitoring and reporting documentation, a one-year re-audit of 120 transfusion episodes administered between January and June 2025 was performed using the same criteria and abstraction approach.

resultsAt baseline, patient identification was documented in 96.8% (n = 213/220) of episodes. Monitoring and completion documentation were suboptimal, with 15-minute observation documented in 69.5% (n = 153/220) and end-of-transfusion vital signs in 80.9% (n = 178/220). Suspected transfusion reactions were similar across cycles, occurring in 2.7% (n = 6/220) at baseline and 2.5% (n = 3/120) at re-audit; formal hemovigilance reporting improved from 33.3% (n = 2/6) of suspected reactions to 100.0% (n = 3/3). In the re-audit, 15-minute observation documentation increased to 90.0% (n = 108/120), end-of-transfusion vital signs increased to 91.7% (n = 110/120), and 100.0% (n = 3/3) of suspected reactions were officially reported.

conclusionWhile foundational pre-transfusion safety steps were strong, baseline deficits were evident in active monitoring and hemovigilance reporting. The quality improvement intervention was associated with substantial improvements sustained at one-year re-audit. Continued reinforcement of standardized documentation and periodic repeat audits are recommended to maintain progress and achieve full compliance with safety-critical standards.

Indexed as

clinical audithaemovigilancetransfusion safetyvital-sign monitoringwho guidelines

Identifiers

PMID41783885
PMCPMC12954818

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.