Evidence map›Paper›PMID 41783842›Full record

ArticleThe journal of advanced prosthodontics2026

Effect of scan body geometric configuration and library design on digital implant impression accuracy.

Hong Seok Moon, Ahreum Choi, Kyung Chul Oh, Minji Sun, Jaeyoung Kim

Abstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hong Seok MoonDepartment of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0001-8118-8145
Ahreum ChoiDepartment of Dental Industry, Yonsei University College of Dentistry, Seoul, Republic of Korea.ORCID https://orcid.org/0009-0004-4752-9080
Kyung Chul OhDepartment of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-4584-2597
Minji SunDepartment of Prosthodontics, Ewha Womans University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-7402-2128
Jaeyoung KimDepartment of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-2412-891X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this MATERIALS AND

methodsNine scan body geometries were fabricated by combining three body heights (4, 5, and 6 mm) with three FIS lengths (1, 2, and 3 mm). Digital impressions were superimposed onto truncated or full-geometry library files. Linear deviation (ΔD) and angular deviation (ΔA) were calculated by comparing aligned scan bodies with coordinate measuring machine references. Linear and angular deviations were compared between library types using the Mann-Whitney U test, and differences among body heights and FIS lengths were evaluated using the Kruskal-Wallis test with Dunn's post-hoc test (α = .05).

resultsLinear deviation remained within a comparable range, and most geometry-library comparisons did not show a significant difference from body height, FIS length, or library morphology (

conclusionDigital implant registration remained stable across most configurations. Shortened scan bodies performed reliably when FIS dimensions were preserved. Angular accuracy was more sensitive to geometry-library interactions, with truncated libraries improving stability.

Indexed as

AccuracyFlat indexing surfaceIntraoral scanScan bodyShort scan body

Identifiers

PMID41783842
PMCPMC12956435

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.