Evidence map›Paper›PMID 41783839›Full record

ArticleThe journal of advanced prosthodontics2026

The effect of implant-abutment connection fit and proximal contact tightness on screw loosening.

Hilal Gülgezen Aydın, Volkan Şahin

Abstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Hilal Gülgezen AydınDepartment of Prosthodontics, Faculty of Dentistry, Tekirdağ Namık Kemal University, Tekirdağ, Türkiye.ORCID https://orcid.org/0000-0002-0230-7036
Volkan ŞahinDepartment of Prosthodontics, Faculty of Dentistry, Kırıkkale University, Kırıkkale, Türkiye.ORCID https://orcid.org/0000-0002-4955-9943

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aims to evaluate how the fit between implant-abutment connection surfaces and the proximal contact tightness of crowns affect abutment screw loosening. MATERIALS AND

methodsForty implants with internal hex connections were placed in stainless steel models in the maxillary right first molar region. Monolithic zirconia crowns with standard and 15 µm reduced proximal contacts were used with abutments with standard and 25 µm horizontally reduced hex connections. After cementation, four groups of specimens-standard abutment/standard proximal contact (control), reduced fit abutment/standard proximal contact (RS), standard abutment/reduced proximal contact (SR), and reduced fit abutment/reduced proximal contact (RR)-were subjected to simultaneous thermocycling (± 5 - 55℃) and chewing cycles (100 N, 1.6 Hz, 40 mm/sec lateral and vertical speed, lateral movement: 6 mm, vertical movement: 0.5 mm). Removal torque values (RTVs) were measured using a digital torque meter. Data were analyzed using two-way ANOVA and the Bonferroni test (α = .05).

resultsAll groups exhibited statistically significant differences compared to each other and the control group (

conclusionThe findings indicate that inadequate proximal contacts and horizontal misfit of the implant-abutment connection may lead to torque loss and screw loosening.

Indexed as

Dental implant-abutment connectionProximal contactScrew loosening

Identifiers

PMID41783839
PMCPMC12956434

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked