Evidence map›Paper›PMID 41783350›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Novel design of tubular metamaterials with sign-switchable Poisson's ratio and tunable mechanical properties for intestinal stents.

Yongtao Lyu, Volha Siniauskaya, Jian Jiang, Hao Wang, Lingqi Meng, Sergei Bosiakov, Mohammed Rafiq Abdul Kadir

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yongtao LyuDepartment of Spinal Surgery, Central Hospital of Dalian University of Technology, Dalian University of Technology, Dalian, China.
Volha SiniauskayaDepartment of Spinal Surgery, Central Hospital of Dalian University of Technology, Dalian University of Technology, Dalian, China.
Jian JiangDepartment of Spinal Surgery, Central Hospital of Dalian University of Technology, Dalian University of Technology, Dalian, China.
Hao WangDepartment of Engineering Mechanics, Dalian University of Technology, Dalian, China.
Lingqi MengDUT-BSU Joint Institute, Dalian University of Technology, Dalian, China.
Sergei BosiakovFaculty of Mechanics and Mathematics, Belarusian State University, Minsk, Belarus.
Mohammed Rafiq Abdul KadirDepartment of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Current intestinal stents used to restore patency face limitations due to the rigidity of metal structures and the premature degradation of biopolymer alternatives. Therefore, there is a critical need to develop stents that are flexible, radially strong, and able to adapt to the dynamic conditions within the body. Methods: This study introduces a novel tubular mechanical metamaterial featuring a sign-switchable Poisson's ratio and tunable mechanical properties, achieved by integrating hexagonal unit cells with positive Poisson's ratio and re-entrant unit cells with negative Poisson's ratio. Experimental uniaxial compression tests and finite element analyses were performed to validate the proposed design and assess its mechanical performance. Results: The structure exhibits a negative Poisson's ratio under tensile loading across all configurations, whereas under compression, the Poisson's ratio was transited from negative to positive due to self-contact between triangular struts, enabling the distinctive sign-switching behavior. Experimental uniaxial compression tests and finite element analyses were performed to validate the proposed design and assess its mechanical performance. Results reveal that the geometric gap between the horizontal struts in the concave unit cells serves as a crucial tuning parameter: increasing this gap delays the onset of sign-switching during compression while exerting minimal influence on the tensile response. The stiffness, yield strength, and energy absorption capacity are shown to be highly adjustable through this geometric control. Discussion: Overall, the metamaterial demonstrates superior energy absorption and tunable stiffness, making it a promising candidate for applications in intestinal stents.

Indexed as

adjustable energy absorptionintestinal stentssign-switchable Poisson’s ratiotubular mechanical metamaterialtunable stiffness

Identifiers

PMID41783350
PMCPMC12953497

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.