Evidence map›Paper›PMID 41783334›Full record

ArticleArthroplasty today2026

Comparison of High-tensile Suture and 16-gauge Wire for Prophylactic Fixation in Total Hip Arthroplasty: A Biomechanical Study.

Sergio F Guarin Perez, Gongyin Zhao, Ichiro Tsukamoto, Joshua R Labott, Diego J Restrepo, Ta-Wei Tai, Alexander W Hooke, Chunfeng Zhao, Rafael J Sierra

Abstract read
In one paragraph

Article in Arthroplasty today, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sergio F Guarin PerezDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
Gongyin ZhaoDivision of Orthopedic Research, Biomechanics Laboratory, Mayo Clinic, Rochester, MN, USA.
Ichiro TsukamotoDivision of Orthopedic Research, Biomechanics Laboratory, Mayo Clinic, Rochester, MN, USA.
Joshua R LabottDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
Diego J RestrepoDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
Ta-Wei TaiDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
Alexander W HookeDivision of Orthopedic Research, Biomechanics Laboratory, Mayo Clinic, Rochester, MN, USA.
Chunfeng ZhaoDivision of Orthopedic Research, Biomechanics Laboratory, Mayo Clinic, Rochester, MN, USA.
Rafael J SierraDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Prophylactic cerclage fixation may reduce fracture risk after total hip arthroplasty. Traditionally performed with wire or cables, high-tensile suture is a novel alternative not previously evaluated. This study compared peak torque to failure of cemented and cementless femoral stems using either 16-gauge wire or high-tensile suture in a synthetic femur model. Methods: Sixteen collarless triple-taper (TT) stems (8 calcar wire, 8 calcar suture) and 27 taper-slip (TS) stems were tested: 7 each with calcar suture, diaphyseal wire, and diaphyseal suture, and 6 with calcar wire (one excluded). Stems were press-fit or cemented into composite femora. Fixation was applied above the lesser trochanter (calcar) or 2 cm below (diaphyseal). Sutures were tensioned to 80 N. A servohydraulic system applied a 2000 N load with 1°/s internal rotation until failure. Power analysis supported 7 specimens per group to detect a 30 Nm difference. Two-sample and noninferiority Results: For TT stems, peak torque was 92.7 ± 11.4 Nm with calcar wire and 102.6 ± 41.4 Nm with calcar suture; suture was noninferior (P = .038). For TS stems, torque was 148.2 ± 38.6 Nm (calcar wire), 118.3 ± 30.2 Nm (calcar suture), 164.9 ± 21.5 Nm (diaphyseal wire), and 159.4 ± 30.0 Nm (diaphyseal suture). Noninferiority in TS stems was not established. Diaphyseal suture exceeded calcar suture ( Conclusions: High-tensile suture was comparable to wire for calcar fixation in collarless TT stems. In TS stems, noninferiority was not demonstrated. Suture constructs may offer practical advantages and warrant further study.

Indexed as

BiomechanicsCalcar fixationDiaphyseal fixationHip arthroplastyPeriprosthetic fracture

Identifiers

PMID41783334
PMCPMC12954323

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.