Evidence map›Paper›PMID 41783076›Full record

ArticleJournal of vascular surgery cases and innovative techniques2026

The catheter rendezvous technique for safe wire removal during Najuta prothesis implantation.

Amir Arnautovic, Artis Knapsis, Sofie Lückerath, Waseem Garabet, Hubert Schelzig, Markus Udo Wagenhäuser

Abstract read
In one paragraph

Article in Journal of vascular surgery cases and innovative techniques, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Amir ArnautovicClinic of Vascular and Endovascular Surgery, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University, Duesseldorf, Germany.
Artis KnapsisClinic of Vascular and Endovascular Surgery, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University, Duesseldorf, Germany.
Sofie LückerathClinic of Vascular and Endovascular Surgery, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University, Duesseldorf, Germany.
Waseem GarabetClinic of Vascular and Endovascular Surgery, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University, Duesseldorf, Germany.
Hubert SchelzigClinic of Vascular and Endovascular Surgery, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University, Duesseldorf, Germany.
Markus Udo WagenhäuserClinic of Vascular and Endovascular Surgery, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University, Duesseldorf, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fenestrated aortic arch prostheses represent a robust therapeutic option for select pathologies. The Najuta is a semicustomized stent graft designed to achieve reliable sealing zones for the supra-aortic vessels through a variable number of fenestrations. A defining aspect of the procedure is the creation of a through-and-through wire (TATW), which is executed through a transaxillary approach via the fenestration of the brachiocephalic trunk. The omission of the catheter rendezvous technique for safe removal of the TATW, as described herein, may result in severe complications, including damage to the fabric or secondary dislocation of the stent graft, potentially leading to catastrophic outcomes such as aortic dissection or stroke. During implantation, the Najuta prosthesis is introduced using a 4-m soft Terumo wire configured in a transaxillary-transfemoral TATW arrangement. A loop is then formed around the aortic valve, facilitating the safe advancement of the prosthesis into the aortic arch. This loop configuration must be untied after implantation. If this is performed carelessly, excessive tension may be exerted on the medial edge of the brachiocephalic trunk fenestration, which may potentially lead to fabric damage or secondary dislocation of the entire prosthesis. To avoid this, catheters are inserted via both the transaxillary and transfemoral access points. These catheters meet at the loop area in a controlled "rendezvous" maneuver, enabling the safe removal of the TATW via the transaxillary access. The catheter rendezvous technique ensures the safe extraction of the loop TATW during the implantation of the Najuta prosthesis, thereby enhancing procedural safety and minimizing patient risk.

Indexed as

Aortic arch prothesisEndovascularFenestrated prothesisPenetrating aortic ulcer

Identifiers

PMID41783076
PMCPMC12954192

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked