ArticlePhysics and imaging in radiation oncology2026
Comparative analysis of artificial intelligence-based contouring of cardiac substructures on computed tomography scans for radiation therapy.
Article in Physics and imaging in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Artificial Intelligence in Cardiovascular Medicine: A Giant Step in Personalized Medicine?Journal of personalized medicine · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
20 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and purpose: Artificial intelligence-based contouring tools enable assessment of radiation doses to cardiac substructures beyond mean heart dose. This study examined inter-solution variations in raw contours and the impact of non-contrast enhancement on contours for each solution. Materials and methods: Contrast-enhanced (CE) and non-contrast-enhanced (NCE) breath-hold thoracic computed tomography (CT) scans, sequentially acquired during the same imaging session for twenty lung cancer patients, were used. Seven commercial, three open-source, and one in-house AI solutions were evaluated. On CE-CTs, solutions were compared using Dice Similarity Coefficient (DSC) and 95th percentile of Hausdorff distance (HD95) across each pair of solutions. Then, the effect of non-contrast enhancement on contours was assessed using volume ratios between NCE-CT and CE-CT for each solution. Results: Typically, ten cardiac substructures were contoured by most of the solutions. For the whole heart, cardiac chambers and great vessels, the average median DSC was above 0.8 for 55 of the 123 structure-solution pairs (45%), and the average median HD95 was below 10 mm for 47 of the 123 structure-solution pairs (38%). For the coronary arteries, the average median DSC ranged between 0.03 and 0.50 and the average median HD95 ranged between 19 mm and 70 mm. Non-contrast enhancement influenced results variably; volume differences were below 10% for 84 of the 123 structure-solution pairs (68%). Conclusions: Automatic contouring solutions exhibited inter-solution variability for cardiac substructures that may have clinical impact. Greater transparency and standardisation of models, ideally through international consensus and shared datasets, are essential.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.