Evidence map›Paper›PMID 41779325›Full record

ArticleEJNMMI radiopharmacy and chemistry2026

Co-57-based intercomparison of TLC scanners and dose calibrators for low-activity radiochemical purity assessment in radiopharmaceutical quality control.

Marietta Straub, Michel Leresche, Claude Pilloud, Rolf Hesselmann, Nicolas Stritt, Ruslan Cusnir

Abstract read
In one paragraph

Article in EJNMMI radiopharmacy and chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Marietta StraubInstitute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. marietta.straub@chuv.ch.ORCID http://orcid.org/0000-0002-1156-4085
Michel LerescheInstitute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Claude PilloudInstitute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Rolf HesselmannFederal Office of Public Health, Bern, Switzerland.
Nicolas StrittFederal Office of Public Health, Bern, Switzerland.
Ruslan CusnirInstitute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThin layer chromatography scanners and dose calibrators are commonly used to assess radiochemical purity of radiopharmaceutical preparations. Strict quality assurance programs surveyed by regulatory bodies exist for dose calibrators, but they primarily focus on clinical activity ranges, typically tens to hundreds of megabecquerels (MBq). These programs are not designed to evaluate performance at the lower activity levels used during radiopharmaceutical quality control, in the range of just a few MBq or less. For thin layer chromatography scanners, to our knowledge, no supervised quality control program exists. As a result, current practices may overlook potential inaccuracies at these low but critical activity levels, potentially affecting the reliability of radiochemical purity assessments, guaranteeing radiopharmaceutical quality of patient injections.

resultsTo address this gap, in collaboration with the Swiss Federal Office of Public Health, we organized an intercomparison campaign for radiochemical purity testing employing in-house fabricated cobalt-57 (Co-57) strips simulating a chromatogram of a radiopharmaceutical preparation for quality control. Co-57, with its longer half-life, closely simulates the gamma emissions of technetium-99m (Tc-99m), a nuclide widely used in nuclear medicine. Co-57 thin layer chromatography strips were prepared and characterized, before being sent to nuclear medicine centers for measurement and radiochemical purity assessment. 31 centers participated, in total 41 quality control measurements were performed using dose calibrators and/or thin layer chromatography scanners to assess the radiochemical purity. All 27 dose calibrator results were within specifications, except for one result that overestimated the radiochemical purity. Within 14 thin layer chromatography scanner results, 3 were out of tolerance.

conclusionRegular participation in intercomparison campaigns is essential for harmonizing practices and ensuring reproducible, reliable results. Thin layer chromatography results can be affected by scanner settings, procedural variations, and subjective peak integration. By comparing thin layer chromatography scanners and dose calibrators, we identified potential instrument biases and methodological discrepancies when values were out of tolerance. Our intercomparison contributed to improving the performance and comparability of radiochemical purity measurements across Swiss nuclear medicine institutions.

Indexed as

Nuclear medicineQuality controlRadiochemical purityRadiopharmacy

Identifiers

PMID41779325
PMCPMC13069025

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.