Evidence map›Paper›PMID 41779240›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2026

Low-profile 2.7 mm VA-LCP plates vs. 3.5 mm LCP plates for midshaft clavicle osteosynthesis: a retrospective comparison.

D Brun, Y Lecoultre, B J M van de Wall, F Pretz, S Geuss, R Babst, B C Link, F J P Beeres

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

D BrunFaculty of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland. dominik.brun@luks.ch.
Y LecoultreFaculty of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland.ORCID http://orcid.org/0000-0002-2291-8272
B J M van de WallFaculty of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland.ORCID http://orcid.org/0000-0003-1882-8626
F PretzFaculty of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland.ORCID http://orcid.org/0009-0007-8643-369X
S GeussDepartment of Orthopedic and Trauma Surgery, LUKS Lucerne, Lucerne, Switzerland.
R BabstFaculty of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland.ORCID http://orcid.org/0000-0002-7606-1358
B C LinkDepartment of Orthopedic and Trauma Surgery, LUKS Lucerne, Lucerne, Switzerland.ORCID http://orcid.org/0000-0002-3289-6935
F J P BeeresFaculty of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland.ORCID http://orcid.org/0000-0002-7277-3438

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeImplant related irritation and subsequent removal are one of the main disadvantages of clavicle plate osteosynthesis. 2.7 mm VA-LCP clavicle plates with a lower profile were introduced in recent years, with the aim to improve fit and reduce plate prominence. This study aims to investigate whether this leads to a lower implant removal rate compared to the older 3.5 mm LCP clavicle plates.

methodsAll patients that underwent single-plate osteosynthesis for midshaft clavicle fractures between 2019 and 2024 in a Swiss level I trauma-center were included. Patients were categorized into two treatment groups: DePuy Synthes 3.5 mm LCP clavicle plates or DePuy Synthes 2.7 mm VA-LCP clavicle plates. Treatment groups were compared regarding healing, complications, and removal rate.

results101 patients were included, 54 with a 2.7 mm VA-LCP plate, and 47 with a 3.5 mm LCP plate. There were no significant differences in implant removal due to hardware irritation (44% versus 49%), overall reintervention rate (46.3% versus 53.2%, p = 0.49), infection (0% versus 4.3% p = 0.21), and refractures (1.9% versus 6.4%, p=0.34). All fractures healed in both groups.

conclusionNewer 2.7 mm VA-LCP clavicle single plating shows similar results in terms of complication and healing rates compared to older 3.5 mm LCP plating. Despite the design aiming for reduced plate-prominence, it does not demonstrate a significant reduction in removal rates in this study. Further studies are needed to ascertain the generalizability of results.

Indexed as

Bone PlatesClavicleFracture Fixation, InternalFractures, BoneAdultAgedFemaleFracture HealingHardware RemovalHumansMaleMiddle AgedRetrospective StudiesClavicle fracturesIrritationPlate designPlate removalSingle plate osteosynthesis

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.