Evidence map›Paper›PMID 41778206›Full record

ArticleEuropean heart journal. Case reports2026

Percutaneous retrieval of the lattice-tip catheter entrapped in post-surgical atrioventricular valve apparatus: two case reports.

Nicoletta Ventrella, Petr Peichl, Corrado Carbucicchio, Predrag Stojadinović, Marco Schiavone, Kazuto Hayasaka, Claudio Tondo, Josef Kautzner

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nicoletta VentrellaDepartment of Electrophysiology, Institute for Clinical and Experimental Medicine (IKEM), Vídeňská 1958, 140 21 Praha 4, Prague, Czechia.ORCID https://orcid.org/0009-0002-8251-2001
Petr PeichlDepartment of Electrophysiology, Institute for Clinical and Experimental Medicine (IKEM), Vídeňská 1958, 140 21 Praha 4, Prague, Czechia.ORCID https://orcid.org/0000-0002-5625-0071
Corrado CarbucicchioDepartment of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Via Privata Carlo Parea, 4, 20138 Milano MI, Italy.ORCID https://orcid.org/0000-0001-5954-537X
Predrag StojadinovićDepartment of Electrophysiology, Institute for Clinical and Experimental Medicine (IKEM), Vídeňská 1958, 140 21 Praha 4, Prague, Czechia.ORCID https://orcid.org/0000-0002-1487-5823
Marco SchiavoneDepartment of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Via Privata Carlo Parea, 4, 20138 Milano MI, Italy.
Kazuto HayasakaDepartment of Electrophysiology, Institute for Clinical and Experimental Medicine (IKEM), Vídeňská 1958, 140 21 Praha 4, Prague, Czechia.ORCID https://orcid.org/0000-0002-7495-673X
Claudio TondoDepartment of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Via Privata Carlo Parea, 4, 20138 Milano MI, Italy.ORCID https://orcid.org/0000-0001-6200-2114
Josef KautznerDepartment of Electrophysiology, Institute for Clinical and Experimental Medicine (IKEM), Vídeňská 1958, 140 21 Praha 4, Prague, Czechia.ORCID https://orcid.org/0000-0002-1632-6182

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The novel lattice-tip catheter (Sphere-9, Medtronic) enables high-resolution mapping and the ability to switch between radiofrequency and pulsed electric field. Initial experience has shown promising results for treating complex ventricular tachycardias (VTs). However, safety data remain limited, particularly regarding catheter-valve interactions. Cases summary: We report two cases of mechanical entrapment of the lattice-tip catheter in the atrioventricular valves during VT ablation performed via a retrograde transaortic approach. In both cases, the catheter became entangled within the subvalvular apparatus-specifically, in the tricuspid valve of a patient with congenitally corrected transposition of the great arteries and in the mitral valve of a patient who had previously undergone mitral repair. Standard retrieval manoeuvres were unsuccessful, and resolution required percutaneous bailout strategies, specifically transseptal access with bioptomes or forceps. Both procedures were completed without long-term sequelae. These are the first reported cases of large-footprint catheter entrapment in the atrioventricular valve apparatus, highlighting potential mechanical risks associated with its employment in the ventricular setting. Discussion: Our experience emphasizes the importance of preferring transseptal access over retrograde access where feasible, due to its more favourable trajectory and the ability to support safer rescue techniques. Real-time imaging, particularly intracardiac echocardiography, proved essential both for navigation and complication management. While transaortic access remains a viable option, it should be approached with caution, necessitating a thorough understanding of device behaviour and a readiness to manage complications. These observations add important safety considerations for the expanded use of novel ablation platforms in patients with complex ventricular anatomy.

Indexed as

Case reportEntrapmentLarge footprint catheterLattice-tip catheterRetrogradeTransaorticVentricular tachycardia ablation

Identifiers

PMID41778206
PMCPMC12952292

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.