Trial reportAnaesthesiology intensive therapy2026
In-vitro evaluation of the Singularity Air laryngeal mask: a randomized controlled comparison between medical personnel trained and untrained in airway management.
Trial report in Anaesthesiology intensive therapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionSupraglottic airway devices (SGAs) are essential tools in anesthesia and emergency medicine and are easier to teach than endotracheal intubation. The Singularity Air is a recently introduced second-generation laryngeal mask featuring an adjustable shaft angle to improve sealing. This study compared its bench performance between medical personnel with and without airway management training. MATERIAL AND
methodsIn this randomized, controlled in-vitro study, medical personnel each performed five consecutive insertions using the Singularity Air and a comparator device. Study Part A included 20 participants without anesthesia training, who used the LMA Unique. Study Part B included 20 anesthesia-trained staff, who used the Ambu AuraGain. The primary endpoint was time to successful ventilation, defined as visible chest movement of the mannequin. Participants rated insertion difficulty on a 0-10 scale.
resultsOverall insertion success was 99-100% across all devices. For the Singularity Air, median time to successful ventilation on the first attempt was 17 seconds (IQR 10-22) in the non-anesthesiology group and 12 seconds (IQR 10-14) in the anesthesia-trained group (P = 0.287). By the fifth attempt, both groups achieved 7.5 seconds (IQR 5-10 and 6-8, respectively; P = 0.674). Time to ventilation and difficulty ratings were low and comparable to the established devices. The non-anesthesiology participants improved more between the first and fifth attempts than anesthesia-trained participants (P = 0.152).
conclusionsThe Singularity Air laryngeal mask achieved a high success rate and comparable time to ventilation in an in-vitro study when used by acute care medical personnel, regardless of prior airway management training. Larger clinical studies are warranted to confirm these findings and evaluate performance in real patients.