Evidence map›Paper›PMID 41776438›Full record

ArticleBMC medical imaging2026

Comparative evaluation of generative artificial intelligence models for synthetic knee radiograph augmentation in clinical research.

Kwangho Chung, Ji-Hoon Nam, Arailym Dosset, Yong-Gon Koh, Jae Min Kim, Paul Shinil Kim, Jin Woo Lee, Kyoung-Mi Park, Hyuck Min Kwon, Kyoung-Tak Kang

Abstract readComparative Study
In one paragraph

Article in BMC medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kwangho Chung *Department of Orthopedic Surgery, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, 16995, Republic of Korea.
Ji-Hoon Nam *Clevion Co., Ltd., Seoul, 07217, Republic of Korea.
Arailym DossetClevion Co., Ltd., Seoul, 07217, Republic of Korea.
Yong-Gon KohJoint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, 06702, Republic of Korea.
Jae Min KimJoint Reconstruction Center, Department of Radiology, Yonsei Sarang Hospital, Seoul, 06702, Republic of Korea.
Paul Shinil KimDepartment of Orthopaedic Surgery, The Bone Hospital, 67, Dongjak-daero, Dongjak-gu, Seoul, 07014, Republic of Korea.
Jin Woo LeeDepartment of Orthopaedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, 03722, Republic of Korea.
Kyoung-Mi ParkSkyve R&D LAB, Skyve Co., Ltd., Seoul, 07217, Republic of Korea.
Hyuck Min Kwon *Department of Orthopaedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, 03722, Republic of Korea. HYUCK7777@yuhs.ac.
Kyoung-Tak Kang *Clevion Co., Ltd., Seoul, 07217, Republic of Korea. tagi1024@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn this study, the capability of state-of-the-art generative models to synthesize realistic knee radiographs was evaluated to address dataset scarcity in osteoarthritis (OA) research.

methodsThree generative frameworks—Style Generative Adversarial Network3 (StyleGAN3), a stable diffusion + Cycle-consistent Generative Adversarial Network (CycleGAN) pipeline, and Deep Convolutional Generative Adversarial Network (DCGAN)—were trained on 10,042 real knee X-rays. Image quality was assessed using Fréchet Inception Distance (FID) while visual fidelity was evaluated via a Visual Turing Test conducted by two orthopedic surgeons and a musculoskeletal radiologist. Joint Line Convergence Angle (JLCA) was compared between real and synthetic images for anatomical fidelity. Inter- and intra-observer reliability for JLCA was measured using intraclass correlation coefficients (ICC).

resultsStyleGAN3 achieved the best performance (FID 10.84), showing high visual and anatomical fidelity. Integrating Stable Diffusion with CycleGAN showed a moderate FID of 39.79, suggesting that adversarial enhancements improved the diffusion-based synthesis. DCGAN showed lower quality, achieving an FID of 74.15. Expert accuracy in distinguishing real from synthetic images ranged between 36% and 88%, confirming difficulty in visual differentiation. Furthermore, JLCA measurements showed no significant difference between real (4.19 ± 3.07°) and synthetic (3.36 ± 2.19°) images generated by DCGAN (p = 0.12). Similarly, Diffusion + CycleGAN (3.91 ± 2.59° vs. 3.72 ± 2.52°, p = 1.00) and StyleGAN3 (4.27 ± 3.01° vs. 3.60 ± 2.37°, p = 0.25) showed no statistically significant differences. These results indicate that all elevated generative models maintained high anatomical fidelity relative to real radiographs. Inter-observer agreement was strong, with ICC values ranging between 0.83 and 0.97. Intra-observer reliability was also excellent.

conclusionStyleGAN3 generated the most realistic knee radiographs. Diffusion-based pipelines showed promising results when enhanced with adversarial networks. These findings underscore the potential of generative AI to mitigate data limitations in orthopedic research.

Indexed as

Knee JointOsteoarthritis, KneeRadiographyGenerative Adversarial NetworksGenerative Artificial IntelligenceHumansReproducibility of ResultsCycleGANDCGANKneeStyleGAN3X-ray

Identifiers

PMID41776438
PMCPMC13067489

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.