Evidence map›Paper›PMID 41776355›Full record

ArticleMedical physics2026

Motion-compensated diffusion encoding gradients for segmented thick-slab 3D magnetic resonance diffusion-weighted imaging of the brain.

Jens Johansson, Kerstin Lagerstrand, Hanna Hebelka, Stephan E Maier

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jens JohanssonDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Kerstin LagerstrandDepartment of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.
Hanna HebelkaDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Stephan E MaierDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

Funding

Swedish Cancer Society (Cancerfonden)Swedish Childhood Cancer Fund (Barncancerfonden)Swedish government funding of clinical research (ALF)Swedish Research Council (Vetenskapsrådet)
6 · The paper itself

Abstract

backgroundRoutine clinical magnetic resonance diffusion-weighted imaging (DWI) is generally performed with 2D echo planar sequences. A single thick-slab 3D approach could offer higher signal-to-noise ratio and better slice resolution. This has not been adopted due to the difficulty to avoid motion-induced phase error that interfere with multi-shot spatial encoding. PURPOSE: To introduce a new approach for 3D brain DWI: rather than relying on navigator echoes for phase correction, moment-nulled diffusion encoding gradients are used to minimize phase variations at the source.

methodsA standard 2D echo planar imaging sequence was modified to incorporate moment-nulled diffusion encoding gradients and a second phase encoding gradient for spatial multi-shot encoding along the slice select direction. The single thick-slab 3D diffusion-weighted imaging sequence was evaluated with brain scans in healthy volunteers on a 3 Tesla scanner.

resultsIncorporation of both first and second order moment nulling achieved substantial, albeit not comprehensive, reduction of motion-related ghosting artifacts. Without such motion compensation or with first order moment nulling only, motion-related artifacts were consistently more severe. Even though the approach comes with a penalty in echo time-at a diffusion weighting of 1000 s/mm

conclusionsThis proof-of-concept shows that first and second order moment nulling may be a viable avenue for enabling 3D diffusion imaging. At higher slice numbers the SNR

Indexed as

BrainDiffusion Magnetic Resonance ImagingImaging, Three-DimensionalArtifactsHumansMovementSignal-To-Noise Ratioaccelerationgradient momentmoment nullingsegmented 3D‐DWIvelocity

Identifiers

PMID41776355
PMCPMC12957720

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.