Evidence map›Paper›PMID 41776311›Full record

ReviewNPJ cardiovascular health2024

Global implementation and evaluation of atrial fibrillation screening in the past two decades - a narrative review.

Kam Cheong Wong, Tu N Nguyen, Clara K Chow

Abstract readReview
In one paragraph

Review in NPJ cardiovascular health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kam Cheong WongWestmead Applied Research Centre, Sydney Medical School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia. kam.wong@sydney.edu.au.
Tu N NguyenWestmead Applied Research Centre, Sydney Medical School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia.
Clara K ChowWestmead Applied Research Centre, Sydney Medical School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Advances in screening technology have been made in tandem with the aging population and increasing atrial fibrillation (AF) prevalence. While several randomized controlled trials demonstrate the efficacy of AF screening, less evidence has been synthesized addressing the implementation and evaluation of AF screening programs. We systematically searched the PubMed database from 1st January 2000 to 18th January 2024. The search terms included "atrial fibrillation" and "screening" and their synonyms. Articles that described screening implementation, including screening methods, were included. Editorial, commentary, engineering, and basic science articles were excluded. 1767 abstracts were screened, of which 138 full articles were reviewed, and 87 studies were included: 90% from high-income, 8% from upper-middle-income and 2% from lower-middle-income countries/ regions. The screening initiatives included general practice (n = 31), remote self-screening (n = 30), pharmacy (n = 11), community centers and villages (n = 10), hospital (n = 4), and nursing home (n = 1). Most studies used handheld ECG devices (n = 72, 83%), some used wearable devices (n = 13, 15%), and two (2%) used implantable cardiac devices. Comparator groups were described in 17% (15/87) studies: all 6 remote self-screening trials showed superior AF detection rates compared to usual care (these studies applied intermittent screening using handheld ECG devices over 2 weeks to 12 months or wearing ECG patches for continuous monitoring over 2-4 weeks), but 9 trials using systematic and opportunistic screening in primary care settings showed mixed results. Among 72 studies without comparator groups, 18 reported new AF detection rates below 1%, 48 reported 1-10%, 5 reported above 10%, and one reported an AF incidence rate of 2.25% patient-years (95% CI 2.03-2.48). Only 22% (19/87) of studies reported on the implementation evaluation (12 by surveys and 7 by interviews), surveying participant acceptability, usability, and satisfaction, and some studies in general practice and pharmacy interviewing participants and qualitatively evaluating the enablers and barriers to implementation. These studies reported barriers of lack of resources and referral pathways and enablers of having a designated staff member to lead implementation at point-of-care settings. AF screening implementation studies were mainly conducted in high-income countries/ regions. Detection rates were highest in older and higher risk groups, and if longer continuous ECG monitoring was used. Few studies reported details of the implementation of AF screening programs concerning cost, scalability, or comparative effectiveness of remote technology-driven screening approaches versus lower-tech approaches such as pulse palpation. Despite AF screening recommendations existing for some time, we seem to lack the data to effectively scale these initiatives.

Identifiers

PMID41776311
PMCPMC12912355

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.