Evidence map›Paper›PMID 41776218›Full record

ArticleScientific reports2026

Mitigation of inductive coupling effects on buried pipelines using gradient control conductors of overhead line configuration and hippopotamus optimization algorithm.

Kelthoum Hachani, Bentouati Bachir, Djekidel Rabah, Sid Ahmed Bessedik, Ragab A El-Sehiemy

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kelthoum HachaniRenewable Energies and Energy Management Laboratory (LMSEERGE), Engineering Materials, Energy Systems, University of Laghouat, Laghouat, Algeria.
Bentouati BachirRenewable Energies and Energy Management Laboratory (LMSEERGE), Engineering Materials, Energy Systems, University of Laghouat, Laghouat, Algeria.
Djekidel RabahLACoSER Laboratory, University Amar Telidji of Laghouat, BP 37G, Ghardaïa Road, 03000, Laghouat, Algeria.
Sid Ahmed BessedikLACoSER Laboratory, University Amar Telidji of Laghouat, BP 37G, Ghardaïa Road, 03000, Laghouat, Algeria.
Ragab A El-SehiemyElectrical Engineering Department, Faculty of Engineering, Kafrelsheikh University, Kafr El-Shaikh, 33516, Egypt. elsehiemy@eng.kfs.edu.eg.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

By electromagnetic perturbation effect, the extra-high voltage (EHV) overhead transmission lines can cause significant induced voltages and currents on buried metallic pipelines located in the immediate vicinity. These voltages can present a source of hazard both for the structural I ntegrity of the metallic pipeline and for the safety of personnel responsible for operation and maintenance. This paper proposes the quasi-static modeling of the electromagnetic interference to which a buried metallic pipeline will be subjected nearby an extra-high voltage (EHV) overhead transmission line, under steady-state operating conditions of the power electrical grid. Using the electrical network analysis method to evaluate the induced voltage levels and its effects on the buried pipeline; also, to propose a mitigation strategy if necessary. The results obtained show that the values of the AC induced voltage on the buried pipeline are significant and exceed the limits defined by the international NACE standard. They can cause a risk of electrocution for intervention personnel and accelerate the process of metal corrosion. Therefore, the gradient control mitigation technique of the conductors and their optimal geometric arrangement of EHV transmission line using Hippopotamus Optimization (HO) algorithm were proposed to reduce AC induced voltages within the permissible safety limits, according to the requirements of the NACE Standard. Finally, it should be noted that the implementation of these mitigation approaches have led to remarkable results in eliminating potential risks.

Indexed as

Buried metallic pipelinesEHV overhead power lineElectromagnetic interferenceHippopotamus optimization (HO)Nodal network analysis