Evidence map›Paper›PMID 41775984›Full record

ArticleNPJ cardiovascular health2025

From video to vital signs: a new method for contactless multichannel seismocardiography.

Mohammad Muntasir Rahman, Bahram Kakavand, William Van Wurm, William L Holman, Mohammad Reza Movahed, Amirtahà Taebi

Abstract read
In one paragraph

Article in NPJ cardiovascular health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohammad Muntasir RahmanBiomedical Engineering Program, Mississippi State University, Mississippi State, MS, USA.
Bahram KakavandDepartment of Pediatrics, Division of Pediatric Cardiology, Nemours Children's Hospital, Orlando, FL, USA.
William Van WurmPhysician Assistant Studies Program, Mississippi State University, Meridian, MS, USA.
William L HolmanDepartment of Surgery, Division of Cardiothoracic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA.
Mohammad Reza MovahedSarver Heart Center, University of Arizona, Tucson, AZ, USA.
Amirtahà TaebiBiomedical Engineering Program, Mississippi State University, Mississippi State, MS, USA. ataebi@abe.msstate.edu.

Funding

Mississippi Institutions of Higher Learning 2024-04National Science Foundation 2340020
6 · The paper itself

Abstract

Seismocardiography (SCG) is a technique that non-invasively measures the chest wall's local vibrations caused by the heart's mechanical activity. Traditionally, SCG signals have been recorded using accelerometers placed at a single location on the chest wall. This study presents an innovative, cost-effective SCG method that utilizes standard smartphone videos to capture data from multiple chest locations. The analysis of vibrations from multiple points can offer a more thorough understanding of the heart's mechanical activity compared to signals obtained solely from a single chest location. Our approach employs computer vision and deep learning techniques to extract and improve the resolution of multichannel SCG maps obtained by video capture of chest movement. We attached a grid of patterned stickers to the chest surface and recorded videos of chest movements during different respiratory phases. Using a deep learning-based object detector and a template tracking method, we tracked the stickers across video frames and extracted the corresponding SCG signals from sticker displacements. We also developed a robust algorithm to estimate heart rate (HR) from these chest videos and identify the optimal chest location for HR estimation. The method was tested on 28 chest videos captured from 14 healthy participants. The results demonstrated that our method effectively extracted multichannel SCG maps and enhanced their resolution with a mean squared error of 0.1078 and 0.0418 for right-to-left and head-to-foot SCG signals, respectively. We observed intersubject chest vibration patterns corresponding to cardiac events including opening and closure of the heart valves. Moreover, our algorithm accurately estimated HR from 1968 SCG signals extracted from the videos compared to the gold-standard HR measured from each subject's electrocardiogram (bias ± 1.96 SD = 0.04 ± 2.14 bpm; r = 0.99, p < 0.001). The findings from this study underscore the potential of our approach in developing a cardiac monitoring tool using a smartphone that would be widely accessible to the general public and might provide more timely detection of diseases.

Identifiers

PMID41775984
PMCPMC12810757

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked