Commissioning and clinical implementation of an MLC tracking system: An evaluation of AAPM TG-264 guidelines.

André Haraldsson, Tobias Pommer, Emilia Persson, Hedda Enocsson, Mustafa Kadhim, Adalsteinn Gunnlaugsson, Per Munck Af Rosenschöld

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

André HaraldssonRadiation Physics, Department of Hematology, Oncology & Radiation Physics, Skåne University Hospital, Lund, Sweden.ORCID https://orcid.org/0000-0002-1694-3738
Tobias PommerRadiation Physics, Department of Hematology, Oncology & Radiation Physics, Skåne University Hospital, Lund, Sweden.
Emilia PerssonRadiation Physics, Department of Hematology, Oncology & Radiation Physics, Skåne University Hospital, Lund, Sweden.ORCID https://orcid.org/0000-0003-1509-6431
Hedda EnocssonRadiation Physics, Department of Hematology, Oncology & Radiation Physics, Skåne University Hospital, Lund, Sweden.
Mustafa KadhimRadiation Physics, Department of Hematology, Oncology & Radiation Physics, Skåne University Hospital, Lund, Sweden.
Adalsteinn GunnlaugssonDepartment of Hematology, Oncology & Radiation Physics, Skåne University Hospital, Lund, Sweden.
Per Munck Af RosenschöldRadiation Physics, Department of Hematology, Oncology & Radiation Physics, Skåne University Hospital, Lund, Sweden.

Funding

Scania 2022-1459
6 · The paper itself

Abstract

backgroundPrecise radiotherapy relies on accurately targeting tumours while minimising exposure to healthy tissue, yet patient and organ motion complicate treatment delivery. To address intra-fractional motion, multi-leaf collimator (MLC) tracking systems have recently been adopted, adapting beam shapes in real-time. The American Association of Physicists in Medicine (AAPM) Task Group 264 (TG-264) provides guidelines for safely commissioning such tracking systems, yet these guidelines were initially developed for conventional linear accelerators and require evaluation, especially for newer platforms such as Radixact Synchrony. PURPOSE: This study aimed to: (i) evaluate the clinical performance and dosimetric accuracy of the Radixact Synchrony MLC tracking system according to AAPM TG-264 guidelines, from commissioning to clinical implementation; and (ii) critically assess and suggest practical refinements to these guidelines based on experiences with this novel tracking technology.

methodsCommissioning followed TG-264 recommendations, adapted for Radixact Synchrony, utilizing three tracking modes: fiducial-based, markerless adaptive, and marker-based adaptive tracking. Performance was assessed with multiple test systems, including the Delta4 Phantom+, HexaMotion, Quasar platform, and film dosimetry. Measurements included geometric accuracy of phantom trace tracking, dosimetric accuracy of delivered dose to movable phantom, and system latency. Clinical protocols established treatment planning, quality assurance (QA), safety procedures, and clinical decision pathways, focusing on prostate and lung cancer treatments.

resultsThe Synchrony system demonstrated substantial improvements in geometric accuracy compared to non-MLC-tracking approaches. Fiducial-based tracking achieved a root mean square error (RMSE) of 0.76 ± 0.27 mm compared to 3.99 ± 2.84 mm without tracking (p = 0.008), with a mean absolute error (MAE) reduction to 0.36 ± 0.12 mm. Markerless adaptive tracking resulted in similar accuracy (RMSE 0.80 ± 0.15 mm, MAE 0.68 ± 0.15 mm). Dosimetric evaluations revealed consistent improvements, with gamma pass rate ≥ 95% (criteria 2%/2 mm) for tracked plans, significantly outperforming static plans under dynamic conditions (V = 7.0, p = .037). System latency was measured one time at approximately 630 ms for fiducial tracking without external breathing monitoring, slightly exceeding TG-264's ideal threshold (500 ms), yet well within the manufacturer's tolerance (1.5 s). Clinical cases confirmed feasibility, showing median deviations of 2.0-3.9 mm for prostate tracking and around 3.3 mm for markerless lung tracking. Safety protocols and clinical pathways developed during implementation ensured treatment robustness.

conclusionsThe Radixact Synchrony MLC tracking system successfully met TG-264 guidelines, significantly improving geometric and dosimetric accuracy during real-time tumour tracking. However, practical implementation highlighted necessary adaptations to TG-264 recommendations for non-standard platforms such as Radixact, specifically regarding QA protocols, latency tolerance, and handling of the system's unique characteristics (pneumatic MLC, jaw tracking, and flattening-filter-free beams). Our findings underscore the importance of maintaining conservative margins initially, rigorous QA, specialized staff training, and careful patient selection strategies. Further clinical trials focusing on safe margin reduction strategies are essential for optimizing the clinical benefits of advanced tracking technologies.

Indexed as

NeoplasmsParticle AcceleratorsPhantoms, ImagingPractice Guidelines as TopicQuality Assurance, Health CareRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansRadiotherapy Dosageradiotherapy

Identifiers

PMID41775533
PMCPMC12956478

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.